The use of circular surface aerators in wastewater treatment tanks
β Scribed by Achanta Ramakrishna Rao; Bimlesh Kumar
- Publisher
- Wiley (John Wiley & Sons)
- Year
- 2006
- Tongue
- English
- Weight
- 154 KB
- Volume
- 82
- Category
- Article
- ISSN
- 0268-2575
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Aeration experiments were conducted in different sized baffled and unbaffled circular surface aeration tanks to study their relative performance on oxygen transfer process while aerating the same volume of water. Experiments were carried out with the objective of ascertaining the effect of baffle on oxygen transfer coefficient k. Simulation equations govern the oxygen transfer coefficient with the theoretical power per unit volume, X and actual power per unit volume, P~V~. It has been found that, for any given X, circular tanks with baffle produce higher values of k than unbaffled circular tanks, but in terms of actual power consumption unbaffled tanks consume less power when compared to baffled circular tanks to achieve the same value of k. It has been found that in terms of energy consumption, Ξ΅, baffled tanks consume more energy than unbaffled tanks at any value of X. This suggests that the unbaffled circular tank gives a better performance as far as energy consumption is concerned and hence better economy. An example illustrating the energy conservation to aerate the same volume of water in both types of aerators is given. Copyright Β© 2007 Society of Chemical Industry
π SIMILAR VOLUMES
## Abstract Radiationβinduced graft copolymerization of maize starch/acrylic acid has been performed. Also, natural byproduct wood pulp was used after chemical treatment for the removal of metal ions from the investigated wastewater. The surface and structure morphology of the wood pulp and starch/
## Abstract Three types of wastewater, from commercial dyeings containing reactive, disperse and direct dyes were treated using an organic coagulant at pH 5.5 as a first step, with stirring for 5βmin. The second step was oxidation by Fenton's reagent (hydrogen peroxide and iron(II) sulfate) at pH 2
## Abstract **BACKGROUND:** Reject water (return liquor) from dewatering of anaerobically digested activated sludge in municipal wastewater treatment plants contains from 10 to 50% of the phosphorus load when being recycled to the aeration tank. Phosphorus removal from reject water could be an effe