High-performance capillary electrophoresis (HPCE) and high-performance liquid chromatography (HPLC) were developed and applied to the determination of acyclovir (ACV) and guanine (C) in pharmaceuticals. The comparison study showed that two methods gave comparable results in linear range, recovery an
Possible uses of micellar electrokinetic capillary chromatography and high-performance liquid chromatography for the chiral discrimination of some pyrethroids
✍ Scribed by Juraj Ševčík; Karel Lemr; Zdeněk Stránský; Tomáš Večeřa; Jan Hlaváč
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 175 KB
- Volume
- 9
- Category
- Article
- ISSN
- 0899-0042
No coin nor oath required. For personal study only.
✦ Synopsis
Micellar electrokinetic capillary chromatography (MECC) and highperformance liquid chromatography (HPLC) were used for the separation of stereoisomers of the lipophilic uncharged pyrethroids cypermethrin, alphamethrin, permethrin, and fenpropathrin. Different kinds of cyclodextrin (-cyclodextrin, hydroxypropyl-cyclodextrin, dimethyl--cyclodextrin, and ␥-cyclodextrin), surfactants (sodium dodecyl sulphate [SDS] and cetyltrimethylammonium bromide [CTAB]), and cations of background electrolyte (sodium, ammonium, TRIS, and Ammediol) were tested. Optimized conditions (background electrolyte: 50 mmol/l sodium phosphate, pH = 2.5, 150 mmol/l SDS, 150 mg/ml ␥-cyclodextrin) allowed the separation of alphamethrin, the eight cypermethrin stereoisomers being eluted in seven peaks and the separation of two enantiomers of fenpropathrin with resolution R s = 10 and with n ≈ 500,000 theoretical plates. Different experimental conditions, e.g., mobile phase composition, temperature, injected amount, and flow rate, were also optimized in HPLC experiments. The optimal conditions (stationary phase: ChiraDex, 5 µm; mobile phase: 150 mmol triethylamine/l with H 2 SO 4 in water (pH = 3.5) with methanol or acetonitrile; flow rate: 0.8 or 0.6 ml/min; temperature: ambient or 30°, 20°, or 10°C; experimental conditions were modified according to the type of analysis) allow chiral discrimination of alphamethrin enantiomers and analysis of permethrin stereoisomers. MECC offers higher efficiency and shorter analysis time than HPLC, but under tested conditions it was shown that the methods complement each other.
📜 SIMILAR VOLUMES
A two-dimensional high performance liquid chromatography/capillary electrophoresis (HPLC/CE) instrumental set-up was assembled from commercially available equipment. Fractions of the effluent from the HPLC system are collected into microtiter plates with a microfraction collector. The fractions are
Comparative study of silicone and microporous membranes for the separation of some phenols prior to high performance liquid chromatography analysis A membrane separation module has been coupled on-line to a high-resolution liquid chromatographic system. A microcomputer controls the set of operations
The B-domain of recombinant human Factor VIII comprises 909 amino acids and is extensively N-and Oglycosylated, in that at least 20 different sites are occupied by numerous carbohydrate structures. This domain was incubated with trypsin and subjected to liquid chromatography electrospray ionization
Preparative high performance liquid chromatography (HPLC) coupled to tandem mass spectrometry has been used successfully for the isolation of several drug metabolites from urine. Nuclear magnetic resonance (NMR) spectroscopy has been employed to determine the exact chemical structure of these metabo