Perfusion imaging using FOCI RF pulses
β Scribed by Martin N. Yongbi; Craig A. Branch; Joseph A. Helpern
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 634 KB
- Volume
- 40
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Pulsed arterial spinβtagging techniques for perfusion measurements (e.g., echo planar MR imaging and signal targeting with alternating radiofrequency (EPISTAR), flowβsensitive alternating inversion recovery (FAIR), quantitative imaging of perfusion using a single subtraction (QUIPPS), uninverted FAIR (UNFAIR)) generally use hyperbolic secant (HS) pulses for spin inversion. The performance of these techniques depends on the inversion efficiency, as well as the sharpness of the slice profiles. Frequency offset corrected inversion (FOCI) pulses, a recently proposed HS variant, can provide slice profiles with edges that can be up to 10 times sharper than those obtained with conventional HS pulses. In this communication, the implementation and application of the Cβshape FOCI pulse for perfusion imaging in rat brain with the FAIR technique is summarized. Despite providing a more rectangular slice profile than a conventional HS pulse, it is demonstrated both theoretically and experimentally that the FAIR perfusion signal is not increased by using a FOCI tagging pulse. However, the use of a FOCI inversion pulse is shown to significantly minimize static signal subtraction errors that are common with conventional HS pulses. Finally, the suitability of the pulse for perfusion studies is demonstrated, in vivo, on rat brain.
π SIMILAR VOLUMES
## Abstract Magnetic resonance angiography (MRA) was performed by using RF pulses designed to excite a limited spatial extent in two orthogonal directions. The restriction in the second spatial dimension can be used to increase inflow enhancement and to improve small fieldβofβview imaging. A rectan
A method is described for multislice imaging by means of rf pulses which contain a multifrequency excitation spectrum. These pulses label each slice by an individual signal phase and allow the separation of the signals from all the slices by subsequent add/subtract procedures. The image sensitivity
## Abstract An inherent problem of conventional chemical shift imaging is signal contamination into adjacent voxels. This is especially severe in proton spectroscopy of the central nervous system, where the lipid signal from the skull is several orders of magnitude higher than the metabolite resona
## Abstract A method for simultaneous multislice imaging is presented that uses a multislice RF pulse that imparts a different linear phase profile to each slice. During readout, slices are unaliased by using extra sliceβselect gradient lobes, which rephase and dephase individual slices one at a ti
The authors thank Dr. Richard W. Briggs for useful discussions. This work benefited from the financial support of the Whitaker Foundation of Mechanicsburg. Pennsylvania.