Performance of calibration standards for antigen quantitation with flow cytometry

✍ Scribed by R. Lenkei; J. W. Gratama; G. Rothe; G. Schmitz; J. L. D'hautcourt; A. Årekrans; F. Mandy; G. Marti


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
81 KB
Volume
33
Category
Article
ISSN
0196-4763

No coin nor oath required. For personal study only.

✦ Synopsis


In the frame of the activities initiated by the Task Force for Antigen Quantitation of the European Working Group on Clinical Cell Analysis (EWGCCA), an experiment was conducted to evaluate microbead standards used for quantitative flow cytometry (QFCM). An unified window of analysis (UWA) was established on three different instruments (EPICS XL [Coulter Corporation, Miami, FL], FACScan and FACS Calibur [Becton Dickinson, San Jose, CA]) with QC3 microbeads (FCSC, PR). By using this defined fluorescence intensity scale, the performance of several monoclonal antibodies directed to CD3, CD4, and CD8 (conjugated and unconjugated), from three manufacturers (BDIS, Coulter [Immunotech], and DAKO) was tested. In addition, the QIFI system (DAKO) and QuantiBRITE (BDIS), and a method of relative fluorescence intensity (RFI, method of Giorgi), were compared. mAbs reacting with three more antigens, CD16, CD19, and CD38 were tested on the FACScan instrument. Quantitation was car-ried out using a single batch of cryopreserved peripheral blood leukocytes, and all tests were performed as single color analyses. Significant correlations were observed between the antibody-binding capacity (ABC) values of the same CD antigen measured with various calibrators and with antibodies differing in respect to vendor, labeling and possible epitope recognition. Despite the significant correlations, the ABC values of most monoclonal antibodies differed by 20-40% when determined by the different fluorochrome conjugates and different calibrators. The results of this study indicate that, at the present stage of QFCM consistent ABC values may be attained between laboratories provided that a specific calibration system is used including specific calibrators, reagents, and protocols. Cytometry 33: 188-196, 1998.


📜 SIMILAR VOLUMES


A versatile system of high-flow high per
✍ Mohammed Jemal; Zheng Ouyang; Yuan-Qing Xia; Mark L Powell 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 144 KB 👁 1 views

A bioanalytical method has been developed and validated for quantitation of a b-lactam drug candidate and its open-ring biotransformation product utilizing high-flow high-performance liquid chromatography (HPLC) for on-line purification of plasma samples and electrospray tandem mass spectrometry for

The use of high-flow high performance li
✍ M. Jemal; Yuan-Qing; Daisy B. Whigan 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 210 KB 👁 1 views

Two bioanalytical methods have been developed and validated utilizing high flow high performance liquid chromatography (HPLC) for on-line purification of plasma and serum samples and electrospray tandem mass spectrometry for detection and quantitation. Each plasma or serum sample, after mixing with