Performance improvement of multi-stage pulse tube cryocoolers with a self-precooled pulse tube
โ Scribed by L.M. Qiu; X.Q. Zhi; L. Han; Q. Cao; Z.H. Gan
- Book ID
- 118063006
- Publisher
- Elsevier Science
- Year
- 2012
- Tongue
- English
- Weight
- 758 KB
- Volume
- 52
- Category
- Article
- ISSN
- 0011-2275
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
A study on the experimental performance of a hybrid cooler is presented. The two-stage unit consists of a commercial single-stage GM refrigerator to precool a pulse tube stage capable of reaching a minimum temperature of 2.2 K. The pressure waves for both stages are generated separately by independe
We report on the design and test of a three-stage refrigerator, consisting of a liquid nitrogen bath with heat exchangers and two subsequent pulse tube stages. The liquid nitrogen bath serves for precooling the oscillating 4He-gas flow. The PTR stages are operated in orifice and double-inlet mode wi
This paper describes the cooling performance of a pulse tube stage extending to room temperature which is precooled by a singlestage GM refrigerator. With this system it was possible to reach liquid helium temperatures without using rare earth compounds as regenerator material. Instead the regenerat