Percutaneous mitral balloon valvuloplasty—a comparative evaluation of two transatrial techniques
✍ Scribed by Wolfgang Kasper; Helmut Wollschla¨ger; Annette Geibel; Thomas Meinertz; Hanjo¨rg Just
- Book ID
- 115659578
- Publisher
- Elsevier Science
- Year
- 1992
- Tongue
- English
- Weight
- 586 KB
- Volume
- 124
- Category
- Article
- ISSN
- 1097-6744
No coin nor oath required. For personal study only.
📜 SIMILAR VOLUMES
To assess relative merits of the double and single (Inoue) balloon techniques of percutaneous balloon mitral valvuloplasty for treating symptomatic mitral stenosis, 33 patients who underwent dilatation with the double balloon were compared retrospectively with 28 who underwent dilatation with the ln
A middle-aged woman was subjected to balloon mitral valvuloplasty using a bifoil balloon catheter. After inflation the balloon failed to detlate in spite of negative suction, probably due to a kink. The balloon was perforated with a transseptal puncture needle in order to deflate it and save open he