𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Percutaneous coronary intervention using a novel 4-French coronary accessor

✍ Scribed by Satoshi Takeshita; Takaaki Shiono; Ayumu Takagi; Takenari Ito; Shigeru Saito


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
146 KB
Volume
72
Category
Article
ISSN
1522-1946

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Background: Percutaneous coronary intervention (PCI) using a guiding catheter with small diameters may have a favorable impact on vascular access complications and patient morbidity. Here, we report the initial results of PCI using a 4‐Fr coronary accessor. Methods: A total of 31 patients underwent 4‐Fr PCI. Exclusion criteria for 4‐Fr PCI were (1) lesions associated with large side branches requiring wire protection or kissing balloon technique and (2) planned use of angioplasty devices which were not compatible with 4‐Fr catheter. Results: A total of 36 lesions, including 4 chronic total occlusions (CTO), were treated. Access sites included radial artery in 19 patients (61%), brachial artery in 8 (26%), and femoral artery in 4 (13%). Four‐Fr PCI was successful in 34 of 36 lesions (94%) in 29 of 31 patients (94%). One of the two unsuccessful patients was a case of CTO, and the other a case of tortuous right coronary artery. In both, crossover to a 6‐Fr PCI was necessary. Among successfully treated 34 lesions of the 29 patients, coronary stents were deployed in 30 lesions (88%). There were no stent dislodgements or inadequate contrast opacification. No access‐site related complications including radial artery occlusion were observed. Conclusions: PCI with a 4‐Fr coronary accessor is a viable alternative to the use of larger guide catheters. The advent of 4‐Fr stent delivery system may afford a less invasive approach for the treatment of patients with coronary artery disease. Β© 2008 Wiley‐Liss, Inc.


πŸ“œ SIMILAR VOLUMES


A randomized trial of 5 vs. 6 French tra
✍ Johannes B. Dahm; Dirk Vogelgesang; Astrid Hummel; Alexander Staudt; Henry VΓΆlzk πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 53 KB πŸ‘ 1 views

## Abstract Transradial coronary interventions (TCI) are occasionally limited by radial spasms and postprocedural radial occlusions, which are related to the radial diameter and which possibly may be reduced by the use of smaller guiding catheter. However, 5 Fr, 0.058β€³ lumen diameter guiding cathet

Percutaneous transluminal coronary angio
✍ Moles, V. P. ;Meier, B. ;Urban, P. ;De La Serna, F. ;Pande, A. K. πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 290 KB πŸ‘ 2 views

## Abstract The use of 4 French (4F) diagnostic catheters as guiding catheters for coronary angio‐plasty using fixed‐wire balloons in 2 patients with a stenosis of the right and left anterior descending coronary artery, respectively, is reported.