𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A randomized trial of 5 vs. 6 French transradial percutaneous coronary interventions

✍ Scribed by Johannes B. Dahm; Dirk Vogelgesang; Astrid Hummel; Alexander Staudt; Henry Völzke; Stephan B. Felix


Publisher
John Wiley and Sons
Year
2002
Tongue
English
Weight
53 KB
Volume
57
Category
Article
ISSN
1522-1946

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Transradial coronary interventions (TCI) are occasionally limited by radial spasms and postprocedural radial occlusions, which are related to the radial diameter and which possibly may be reduced by the use of smaller guiding catheter. However, 5 Fr, 0.058″ lumen diameter guiding catheter affords less strength, visibility, and backup. In a randomized study, we investigated procedural and clinical success and vascular access complications of 5 Fr in comparison to 6 Fr guiding catheter. One hundred seventy‐one patients with coronary lesions suitable for at least 5 Fr transradial approach (i.e., normal Allen test, only balloon angioplasty and stent) were randomly assigned for 5 or 6 Fr TCI. The primary combined endpoint was procedural and clinical success, and secondary endpoints were vascular access complications and the occurrence of postprocedural radial occlusions at 1‐month follow‐up. Procedural success was achieved in 95.4% of 5 Fr and 92.9% of 6 Fr patients. Selective cannulation of the coronary ostium failed in 1.1% of 5 Fr and 4.8% of 6 Fr patients (P = 0.08). Minor hematomas without need for surgical repair or blood transfusions occurred in 1.1% (5 Fr) and 4.8% (6 Fr; P = 0.07); 1.1% of 5 Fr and 5.9% of 6 Fr patients (P = 0.05) suffered loss of radial pulse due to radial occlusion. Selected noncomplex coronary lesions can successfully and safely be treated either with 5 or 6 Fr guiding catheters. A tendency of higher procedural success rates and lower vascular access complications was documented after 5 Fr in comparison to 6 Fr TCI. This was particularly the case among patients with small radial diameters. Cathet Cardiovasc Intervent 2002;57:172–176. © 2002 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


A randomized prospective trial of ioxagl
✍ Andrew G.C. Sutton; Victoria J. Ashton; Philip G. Campbell; Dallas J.A. Price; J 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 63 KB

## Abstract We performed a randomized, prospective, double blind trial comparing the use of the ionic dimer contrast agent ioxaglate 320 (Hexabrix) with the nonionic dimer contrast agent iodixanol 320 (Visipaque) in 618 patients undergoing percutaneous coronary intervention (PCI) for stable or unst

Reduction of scatter radiation during tr
✍ Luigi Politi; Giuseppe Biondi-Zoccai; Luca Nocetti; Tiziana Costi; Daniel Monopo 📂 Article 📅 2012 🏛 John Wiley and Sons 🌐 English ⚖ 771 KB

## Abstract Background: Occupational radiation exposure is a growing problem due to the increasing number and complexity of interventional procedures performed. Radial artery access has reduced the number of complications at the price of longer procedure duration. Radpad® scatter protection is a st