𝔖 Bobbio Scriptorium
✦   LIBER   ✦

PC HYPR flow: A technique for rapid imaging of contrast dynamics

✍ Scribed by Julia V. Velikina; Kevin M. Johnson; Yijing Wu; Alexey A. Samsonov; Patrick Turski; Charles A. Mistretta


Book ID
102377428
Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
364 KB
Volume
31
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose:

To improve spatial and temporal resolution and signal‐to‐noise ratio (SNR) in three‐dimensional (3D) radial contrast‐enhanced (CE) time‐resolved MR angiography by means of a novel hybrid phase contrast (PC) and CE MRA acquisition and HYPR reconstruction (PC HYPR Flow).

Materials and Methods:

PC HYPR Flow consists of a CE exam immediately followed by a PC scan used to constrain the HYPR reconstruction of the time series. Temporal resolution of the new method was studied in computer simulations. The feasibility of the new technique was studied in healthy subjects and patients with brain arteriovenous malformations and in a canine model of aneurysms.

Results:

Simulations demonstrated preservation of contrast agent dynamics in proximal vessels, showing better performance than peer methods for acceleration up to 20 in 2D. In vivo, PC HYPR Flow yielded 3D time series with frame rate of 0.5 s and significantly outperformed two peer methods by means of a major increase in spatial resolution (0.8 × 0.8 × 0.8 mm^3^) and arterial/venous ratio, while maintaining necessary temporal waveform fidelity and high SNR.

Conclusion:

This initial study indicates that PC HYPR Flow simultaneously provides 3D isotropic sub‐millimeter spatial resolution, sub‐second temporal reconstruction windows and high SNR level, which may benefit a wide range of CE MRA applications. J. Magn. Reson. Imaging 2010; 31: 447–456. © 2010 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Numerical and experimental study of a no
✍ Longchuan Li; Mark Doyle; Geetha Rayarao; Robert W.W. Biederman; Andreas Anayiot 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 928 KB

## Abstract ## Purpose To use numerical simulation and experimental approaches to introduce a novel phase contrast magnetic resonance (PC‐MR) data processing technique termed Sparse Interleaved Referencing PC‐MR, with potential to improve accuracy, temporal resolution, and signal‐to‐noise ratio (S

Implementation of a rapid inversion-prep
✍ Daniel Prochnow; Dirk Beyersdorff; Carsten Warmuth; Matthias Taupitz; Ole Gemein 📂 Article 📅 2005 🏛 Elsevier Science 🌐 English ⚖ 423 KB

The first step in quantitative pharmacokinetic modeling is to determine the arterial input function (AIF) by deriving the contrast medium (CM) concentration from an appropriate imaging sequence by monitoring changes in either the amplitude or the phase signal of an accommodative artery. The bolus pa

A complex-difference phase-contrast tech
✍ Jason A. Polzin; Marcus T. Alley; Frank R. Korosec; Thomas M Gristn; Yi Wang; Ch 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 805 KB

## Abstract Magnetic resonance (MR) phase‐difference methods work well for measuring volumetric flow rates when the vessel diameter is large compared with the in‐plane voxel dimensions. For small vessels (eg, coronary arteries), partial‐volume effects introduce substantial errors in the measured vo

New bioreactor-coupled rapid stopped-flo
✍ Stefan Buziol; Imtiaz Bashir; Anja Baumeister; Wolfgang Claaßen; Naruemol Noisom 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 174 KB 👁 1 views

## Abstract Knowledge of concentrations of intracellular metabolites is important for quantitative analysis of metabolic networks. As far as the very fast response of intracellular metabolites in the millisecond range is concerned, the frequently used pulse technique shows an inherent limitation. T

Encoding strategies for three-direction
✍ Norbert J. Pelc; Matt A. Bernstein; Ann Shimakawa; Gary H. Glover 📂 Article 📅 1991 🏛 John Wiley and Sons 🌐 English ⚖ 891 KB

## Abstract Three encoding strategies for the measurement of flow velocities in arbitrary directions with phase‐contrast magnetic resonance imaging are presented; their noise and dynamic range performance are compared by means of theoretical analysis and computer simulation. A six‐point measurement