𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Parametric analysis of interfacial stress concentrations in porous coated implants

✍ Scribed by Debra Wolfarth; Mark Filiaggi; Paul Ducheyne


Publisher
Wiley (John Wiley & Sons)
Year
1990
Tongue
English
Weight
630 KB
Volume
1
Category
Article
ISSN
1045-4861

No coin nor oath required. For personal study only.

✦ Synopsis


Porous coated Ti-6AI-4V has a high-cycle fatigue strength that is approximately one-third the strength of the uncoated material. Stress concentrations at the interface between the porous coating and the substrate contribute to this fatigue strength reduction. Modification of the interfacial geometry may reduce the severity of the stress concentrations. The interface between the porous coating and substrate was modeled using two-dimensional finite element analysis. This analysis identified geometric parameters that affect the value of the stress concentration factor, Kt. The effect of five geometric parameters on K , was determined: contact area between porous coating and substrate (CA), sinterneck radius (r), porous coating particle radius (R), interparticle distance ( d ) , and interparticle sintering. Increased contact areas, decreased sinterneck radii, and decreased interparticle distances increased K,, while porous coating particle size had a small effect on Kt. Sintering between neighboring porous coating particles increased K , at the outermost sinternecks, but decreased K, at inner sinternecks. The results can help predict how varying these coating parameters can reduce stress concentrations in a porous coated material.


📜 SIMILAR VOLUMES


Stress enhancement and fatigue susceptib
✍ Messersmith, Phillip B. ;Cooke, Francis W. 📂 Article 📅 1990 🏛 John Wiley and Sons 🌐 English ⚖ 704 KB

An elastic stress analysis of porous-coated implant surfaces was performed using the finite element method. Three-hundredpm-diameter metal beads sinter bonded onto an implant surface were modeled with sinter neck radii of 5, 10, 20, and 50 pm. Smooth-surface, single-bead, single-layer, and double-la

Interface mechanics and histomorphometri
✍ Nimb, Lars ;Jensen, Jørgen Steen ;Gotfredsen, Klaus 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 706 KB

## Abstract A canine study was performed to make a histological and biomechanical evaluation of the interface between bone and two different bioceramic implants. A newly developed glass‐ceramic formed by P~2~O~5~, CaO, SiO~2~, and Al~2~O~3~, giving a crystal phase composed of CaP~2~O~6~AlPO~4~SiP

Femoral prosthesis implantation induces
✍ Dr. Harry B. Skinner; Agnes S. Kim; Joyce H. Keyak; C. D. Mote Jr 📂 Article 📅 1994 🏛 Elsevier Science 🌐 English ⚖ 939 KB

## Abstract The objective of this study was to evaluate the effect of implantation of porous‐coated anatomic medullary fitting prostheses on stress in the proximal femur. Three‐dimensional finite element models of a cadaveric femur before and after implantation were used to evaluate the resulting c