Optimization, validation and application of a method for the determination of trichloroethylene in rat plasma by headspace solid-phase microextraction gas chromatography mass spectrometry
✍ Scribed by Yongzhen Liu; Srinivasa Muralidhara; James V. Bruckner; Michael G. Bartlett
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 293 KB
- Volume
- 22
- Category
- Article
- ISSN
- 0269-3879
- DOI
- 10.1002/bmc.1016
No coin nor oath required. For personal study only.
📜 SIMILAR VOLUMES
## Abstract Phenazopyridine hydrochloride is a strong analgesic used in the treatment of urinary tract infections. The aim of the present study was to develop a procedure based on gas chromatography‐mass spectrometry (GC‐MS) for the analysis of phenazopyridine in rat plasma. The method was set up a
## Abstract A rapid, sensitive and selective liquid chromatography–tandem spectrometry method was developed and validated for determination of paeoniflorin in rat plasma using geniposide as the internal standard. The samples were pretreated with solid‐phase extraction using Extract‐Clean™ cartridge
The validation of a fast, reliable, and specific method for the screening, confirmation, and determination of salbutamol in urine with (total) and without (free fraction) a hydrolysis step was developed. Sample urine from different animal species was extracted using Bond Elut certify columns. The de
An SPE-LC-MS/MS method was developed, validated and applied to the determination of nicotine and five major metabolites in human urine: cotinine, trans-3'-hydroxycotinine, nicotine-N-glucuronide, cotinine-N-glucuronide and trans-3'-hydroxycotinine-O-glucuronide. A 500 microL urine sample was pH-adju