✦ Synopsis


Abstract

Conditions for maximizing resolution and signal‐to‐noise ratios in fluorescence scanning densitometry of separations obtained by high performance thin‐layer chromatography are described. Resolution was found to be independent of most instrument parameters with a small decrease observed at wide slit widths. Signal was found to be markedly dependent on experimental parameters such as slit width, slit height, sensitivity setting, and the time constant of electronic filters. For recording chromatograms a slit width of 1.00 mm, a slit height slightly greater than the spot diameter, a low sensitivity setting (50 mV), electronic filtering, and a scan rate of 24 or 48 mm min^βˆ’1^ are commensurate with minimum recording time and maximum sample detectability without incurring a significant decrease in resolution.


πŸ“œ SIMILAR VOLUMES


Determination of lawsone in henna powder
✍ Nagwa S. El-Shaer; Jihan M. Badr; Maha A. Aboul-Ela; Yousry M. Gohar πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 337 KB πŸ‘ 1 views

## Abstract The lawsone content has been evaluated quantitatively in eight commercial henna powders and two collected henna leaves. The phenolic, chloroform‐soluble fraction of the majority of the examined samples showed the presence of lawsone and two other pigments. Here we aimed to optimize high

Nondestructive Detection of Gangliosides
✍ J. Muthing; D. Heitmann πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 382 KB

A simple and effective procedure for the isolation and purification of gangliosides by preparative thin-layer chromatography is described. The method is based on nondestructive visualization of gangliosides on silica gel-precoated thin-layer chromatography plates by staining with uncharged lipophili

Detection of gangliosides with the fluor
✍ Johannes MΓΌthing; Frank Unland πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 441 KB πŸ‘ 1 views

A new method for the detection of gangliosides based on the lipophilic fluorescence agent 4-(N,Ndihexadecyl)amino-7-nitrobenz-2-oxa-1,3-diazole (NBD dihexadecylamine) and its application for preparative high performance thin layer chromatography is described. Brain gangliosides were chromatographed

Determination of atrasentan by high perf
✍ Peter D. Bryan; Lisa B. Sapochak; Michelle M. Tames; Robert J. Padley; Tawakol A πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 108 KB πŸ‘ 2 views

Atrasentan is an endothelin antagonist selective for the ET A receptor in development at Abbott Laboratories for the treatment of cardiovascular disease and cell proliferation disorders. A simple and sensitive chromatographic method for the determination of atrasentan in human plasma has been develo