✦ Synopsis


The profile of the pressure drop of cooling gas was measured in operational tests of 7 and 10 kA current leads. The current leads have spiral-shaped fins which permit both high heat exchange efficiency and reliability against thermal runaway. A general design chart was employed to determine the geometrical dimensions and to estimate the operational performance of the leads. The spiral-fin current leads exhibited good performances in the operational tests. The heat flow from the cold end of the 7 and 10 kA leads was 7.47 and 10.4W, respectively, in the self-sustained condition. A constant friction factor of 0.0715 was found to reproduce the experimental pressure drop profile along the cooling path. This friction factor can be employed to estimate the pressure drop of the cooling gas of current leads in general designs.


πŸ“œ SIMILAR VOLUMES


Influence of copper quality on overload
✍ HansjΓΆrg KΓΆfler; Franz Ramsauer πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 263 KB

Calculation of current leads for superconducting devices usually is performed for a specific conductor arrangement and conductor quality foreseen for construction of the lead. Variation of specific conductivity of the conductor offers an additional path for optimizing the lead to specific requiremen