Resins synthesized from qumohn-b-01 and resorcmol or hydroqmnone, with furfuraldehyde, formaldehyde or benzaldehyde as cross-hnkmg agent, were used for the preconcentrafion of nanogram amounts of lead The rate of exchange and activation energy of lead exchange were calculated Column separations of l
On-line preconcentration and determination of trace platinum by flow-injection atomic absorption spectrometry
✍ Scribed by A. Cantarero; M.M. Gómez; C. Cámara; M.A. Palacios
- Publisher
- Elsevier Science
- Year
- 1994
- Tongue
- English
- Weight
- 584 KB
- Volume
- 296
- Category
- Article
- ISSN
- 0003-2670
No coin nor oath required. For personal study only.
✦ Synopsis
The analytical performance of a platinum preconcentration method using a 0.01 M HNO, carrier solution and an alumina microcolumn is discussed. On-line preconcentration is followed by flame atomic absorption spectrometry (FAAS), and off-line preconcentration by graphite furnace atomic absorption spectrometry (GFAAS). The preconcentration factors were 600 for FAAS (25 ~1 elution volume) and 30 for GFAAS (500 ~1 elution volume), both with a U-ml sampling volume. The detection limits in these conditions were 0.02 mg l-l, and relative standard deviation (R.S.D.) of 9% (0.1 mg 1-l solution, n = 5) for FAAS and 0.33 pg l-l, and a R.S.D. of 7% (5 pg 1-l solution )1= 5) for GFAAS. The proposed method is suitable for platinum determination in natural water samples.
📜 SIMILAR VOLUMES
A desolvation device was connected to a microcolumn (40 mm X 3.0 mm i.d.) in which 8-hydroxyquinoline-5sulphonic acid was immobilized on the substrate of active carbon-silica gel. The analyte and 1.0 M sodium acetate-acetic acid buffer solution (pH 5.6) were mined and pumped through the microcolumn.
A flow injection on-line coprecipitation preconcentration system with diethyldithiocarbamate (DDTC) chelate of copper used as the coprecipitate carrier was coupled with flame atomic absorption spectrometry (FAAS) for the determination of trace silver. Silver was on-line coprecipitated with DDTC-Cu(I
1,10 Phenanthroline (phen) has been tested as a complexing agent, which is more stable and selective than sodium-diethyldithiocarbamate (DDTC) and ammonium-pyrrolidinedithiocarbamate (APDC), for on-line preconcentration of copper on RP-C 18 material in a microcolumn with a flow injection-flame atomi
Palladium was determined in pharmaceuticals by direct graphite furnace atomic absorption spectrometry (GFAAS) method. The detection limit was 0.1 mg/g in 5% solution; the recovery of 0.5-2.0 mg/g Pd spike was close to 100%. The flow injection GFAAS method was worked out using oxime and iminodiacetic
A flow-injection on-line 8531 fibre column separation and preconcentration system is proposed for the efficient flame atomic absorption spectrometric determination of trace gold in ores and metallurgical samples. A flow manifold with a pump and two valves was assembled to conduct the operating cycle