𝔖 Bobbio Scriptorium
✦   LIBER   ✦

On-line preconcentration and determination of trace platinum by flow-injection atomic absorption spectrometry

✍ Scribed by A. Cantarero; M.M. Gómez; C. Cámara; M.A. Palacios


Publisher
Elsevier Science
Year
1994
Tongue
English
Weight
584 KB
Volume
296
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


The analytical performance of a platinum preconcentration method using a 0.01 M HNO, carrier solution and an alumina microcolumn is discussed. On-line preconcentration is followed by flame atomic absorption spectrometry (FAAS), and off-line preconcentration by graphite furnace atomic absorption spectrometry (GFAAS). The preconcentration factors were 600 for FAAS (25 ~1 elution volume) and 30 for GFAAS (500 ~1 elution volume), both with a U-ml sampling volume. The detection limits in these conditions were 0.02 mg l-l, and relative standard deviation (R.S.D.) of 9% (0.1 mg 1-l solution, n = 5) for FAAS and 0.33 pg l-l, and a R.S.D. of 7% (5 pg 1-l solution )1= 5) for GFAAS. The proposed method is suitable for platinum determination in natural water samples.


📜 SIMILAR VOLUMES


Determination of trace amounts of lead b
✍ Rajesh Purohit; Surekha Devi 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 552 KB

Resins synthesized from qumohn-b-01 and resorcmol or hydroqmnone, with furfuraldehyde, formaldehyde or benzaldehyde as cross-hnkmg agent, were used for the preconcentrafion of nanogram amounts of lead The rate of exchange and activation energy of lead exchange were calculated Column separations of l

On-line microcolumn preconcentration wit
✍ Xuejun Peng; Zucheng Jiang; Yun'e Zen 📂 Article 📅 1993 🏛 Elsevier Science 🌐 English ⚖ 512 KB

A desolvation device was connected to a microcolumn (40 mm X 3.0 mm i.d.) in which 8-hydroxyquinoline-5sulphonic acid was immobilized on the substrate of active carbon-silica gel. The analyte and 1.0 M sodium acetate-acetic acid buffer solution (pH 5.6) were mined and pumped through the microcolumn.

Determination of Trace Amount of Silver
✍ Xueqing Mao; Hengwu Chen; Jinsong Liu 📂 Article 📅 1998 🏛 Elsevier Science 🌐 English ⚖ 90 KB

A flow injection on-line coprecipitation preconcentration system with diethyldithiocarbamate (DDTC) chelate of copper used as the coprecipitate carrier was coupled with flame atomic absorption spectrometry (FAAS) for the determination of trace silver. Silver was on-line coprecipitated with DDTC-Cu(I

Copper determination by flow injection o
✍ Akbar Ali; Hong Shen; Xue Gu; Guangming Xu; Yingxue Ye; Xuefeng Yin 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 144 KB 👁 2 views

1,10 Phenanthroline (phen) has been tested as a complexing agent, which is more stable and selective than sodium-diethyldithiocarbamate (DDTC) and ammonium-pyrrolidinedithiocarbamate (APDC), for on-line preconcentration of copper on RP-C 18 material in a microcolumn with a flow injection-flame atomi

Graphite Furnace Atomic Absorption Spect
✍ Á. Lévai; A. Lásztity; K. Zih-Perényi; Zs. Horváth 📂 Article 📅 1998 🏛 Elsevier Science 🌐 English ⚖ 100 KB

Palladium was determined in pharmaceuticals by direct graphite furnace atomic absorption spectrometry (GFAAS) method. The detection limit was 0.1 mg/g in 5% solution; the recovery of 0.5-2.0 mg/g Pd spike was close to 100%. The flow injection GFAAS method was worked out using oxime and iminodiacetic

Flow-injection on-line fibre column sepa
✍ Weiji Qi; Xing Wu; Chun Zhou; Haizhou Wu; Yingqi Gao 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 507 KB

A flow-injection on-line 8531 fibre column separation and preconcentration system is proposed for the efficient flame atomic absorption spectrometric determination of trace gold in ores and metallurgical samples. A flow manifold with a pump and two valves was assembled to conduct the operating cycle