## Abstract Offโdiagonal component of magnetoโimpedance tensor with pulse excitation is very promising for high sensitivity magnetic field sensor applications. We report novel results on studies of offโdiagonal MI effect and magnetic properties in amorphous glassโcoated microwires with nearlyโzero
โฆ LIBER โฆ
Off-diagonal impedance in amorphous wires and its application to linear magnetic sensors
โ Scribed by Sandacci, S.; Makhnovskiy, D.; Panina, L.; Mohri, K.; Honkura, Y.
- Book ID
- 114649815
- Publisher
- IEEE
- Year
- 2004
- Tongue
- English
- Weight
- 839 KB
- Volume
- 40
- Category
- Article
- ISSN
- 0018-9464
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
Off-diagonal magneto-impedance in amorph
โ
Ipatov, M. ;Zhukova, V. ;Blanco, J. M. ;Gonzalez, J. ;Zhukov, A.
๐
Article
๐
2008
๐
John Wiley and Sons
๐
English
โ 595 KB
Off-diagonal magnetoimpedance in NiFe-Au
โ
Fry, N.; Makhnovskiy, D.P.; Panina, L.V.; Sandacci, S.I.; Mapps, D.J.; Akhter, M
๐
Article
๐
2004
๐
IEEE
๐
English
โ 536 KB
Sensitive and quick response micro magne
โ
Mohri, K.; Panina, I.V.; Uchiyama, T.; Bushida, K.; Noda, M.
๐
Article
๐
1995
๐
IEEE
๐
English
โ 692 KB
Characteristics of an amorphous magnetic
โ
Fusao Hirose; Makoto Takagi; Hideshi Mori; Toru Imura
๐
Article
๐
1994
๐
Elsevier Science
๐
English
โ 543 KB
Theory of the surface acoustic wave/impe
โ
Dezhong Liu; Kang Chen; Aifeng Yin; Kai Ge; Lihua Nie; Shouzhuo Yao
๐
Article
๐
1996
๐
Elsevier Science
๐
English
โ 842 KB
A calibration technique for multiple-sen
โ
B. Marasli; P. Nguyen; J. M. Wallace
๐
Article
๐
1993
๐
Springer
๐
English
โ 764 KB
A calibration technique for multiple-sensor hot-wire probes is presented. The technique, which requires minimal information about the probe geometry, is tested using a four-sensor and a twelve-sensor probe. Two data reduction algorithms are introduced. The first one assumes a uniform velocity over t