## Abstract Female CD 1 mice were exposed from the thirty‐fifth day of age for the remainder of their lives to 2.45 GHz, CW‐microwave radiation at a power density of 3 or 10 m W/cm^2^ (SAR = 2.0 or 6.8 W/kg). Exposures took place 1 h/day, 5 day/week in an anechoic chamber at an ambient temperature
Observing-responses of rats exposed to 1.28- and 5.62-GHz microwaves
✍ Scribed by John O. de Lorge; Clayton S. Ezell
- Publisher
- John Wiley and Sons
- Year
- 1980
- Tongue
- English
- Weight
- 905 KB
- Volume
- 1
- Category
- Article
- ISSN
- 0197-8462
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The effects of microwave irradiation at two different frequencies (1.28 and 5.62 GHz) on observing‐behavior of rodents were investigated. During daily irradiation, eight male hooded rats performed on a two‐lever task; depression of one lever produced one of two different tones and the other lever produced food when depressed in the presence of the appropriate tone. At 5.62 GHz, the observing‐response rate was not consistently affected until the power density approximated 26 mW/cm^2^ at 1.28 GHz, the observing‐response rate of all rats was consistently affected at a power density of 15 mW/cm^2^. The respective whole‐body specific absorption rates (SARs) were 4.94 and 3.75 W/Kg. Measurements of localized SAR in a rat‐shaped model of simulated muscle tissue revealed marked differences in the absorption pattern between the two frequencies. The localized SAR in the model's head at 1.28 GHz was higher on the side distal to the source of radiation. At 5.62 GHz the localized SAR in the head was higher on the proximal side. It is concluded that the rat's observing behavior is disrupted at a lower power density at 1.28 than at 5.62 GHz because of deeper penetration of energy at the lower frequency, and because of frequency‐dependent differences in anatomic distribution of the absorbed microwave energy.
📜 SIMILAR VOLUMES
## Abstract A significant increase was observed in the circulating antibody titers of mice exposed to 9‐GHz pulsed microwaves at an average power density of 10 mW/ cm^2^, two hours per day for five days compared with sham‐irradiated animals. The mice were previously immunized with type III pneumoco
## Abstract Tests of mutagenesis and reproduction were conducted in male rats which were irradiated by 2,450‐MHz, continuous‐wave (CW) microwaves, 4 hr/day from day 6 of gestation to 90 days of age at 5 mW/cm^2^; or 5 hr/day for five days beginning on the 90th day of age at 10 mW/cm^2^; or 4 hr/day
Irradiation by pulsed microwaves (9.4 GHz, 1 ps pulses at 1 ,OOO/s), both with and without concurrent amplitude modulation (AM) by a sinusoid at discrete frequencies between 14 and 41 MHz, was assessed for effects on the immune system of Balb/C mice. The mice were immunized either by sheep red blood
The effect of continuous (CW; 2.45 GHz carrier frequency) or amplitude-modulated (AM; 50 Hz square wave) microwave radiation on the immune response was tested. CW exposures (6 days, 3 h/day) induced elevations of the number of antibody-producing cells in the spleen of male Balb/c mice (+37%). AM mic
## Abstract Microwave‐induced corneal endothelial damage was reported to have a low threshold (2.6 W/kg), and vasoactive ophthalmologic medications lowered the threshold by a factor of 10–0.26 W/kg. In an attempt to confirm these observations, four adult male Rhesus monkeys (__Macaca mulatta__) und