## Abstract Mass spectrometry with electrospray ionization and a magnetic sector instrument was used to detect multiply charged molecules for the non‐covalently bound dimeric subunit protein complexes of horse liver alcohol dehydrogenase (__M__~r~ ∼ 80 000) and the tetrameric complexes of yeast alc
Observation of symmetric denaturation of hemoglobin subunits by electrospray ionization mass spectrometry
✍ Scribed by Xian Wang; Wenjie Zhao; Xin Lin; Bo Su; Jianfeng Liu
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 276 KB
- Volume
- 45
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.1843
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Electrospray ionization mass spectrometry (ESI‐MS) has been used to characterize the denaturation of porcine hemoglobin (Hb) induced by solvent changes. This work provides evidence for the symmetric nature of Hb denaturation and demonstrates that heme losses from α‐ and β‐monomers occur in parallel, in response to the addition of acid and organic co‐solvents in solution. When subject to one of the following solution conditions (pH 3.2–4.0 or 15–30% acetonitrile‐water or 30–45% methanol‐water solution), α‐ and β‐globins undergo symmetric dissociation to release the heme groups, which is detected by ESI‐MS. Circular dichroism (CD) and fluorescence spectroscopy (FS) data show that the acid‐induced and organic solvent‐induced heme release, as observed in the mass spectra, can probably be ascribed to different aspects of the conformational changes taking place in the protein. The acidity of the solvent has a significant effect on the secondary structure, whereas organic content level in solution (15–30% acetonitrile or 30–45% methanol) tends to destroy the tertiary structure of Hb globins, both leading to release of the heme from each subunit. Copyright © 2010 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
Glycated hemoglobin, considered to be the best index for the treatment of diabetes mellitus, was measured by electrospray ionization mass spectrometry (ESI/MS) according to the method proposed by Morris et al. at the 44th ASMS Conference on Mass Spectrometry and Allied Topics, 1996. They compared th
## Abstract By electrospray ionization (ESI) mass spectrometry, micelle solutions of sodium cholate were investigated in detail in the presence and absence of ethanol. The average aggregation number could be evaluated from the spectra acquired under conditions where soft collisions adequate to meas