In the present study, the heat transfer characteristics and the pressure drop of the horizontal concentric tube with twisted wires brush inserts are investigated. The inner diameters of the inner and outer tubes are 15.78 and 25.40 mm, respectively. The twisted wire brushes are fabricated by winding
Numerical study of heat transfer enhancement of a horizontal tube with an eccentrically inserted plate
โ Scribed by C.I. Hung; Y.S. Lin; J.D. Chen
- Publisher
- Elsevier Science
- Year
- 1997
- Tongue
- English
- Weight
- 437 KB
- Volume
- 40
- Category
- Article
- ISSN
- 0017-9310
No coin nor oath required. For personal study only.
โฆ Synopsis
A numerical study is presented for the heat transfer enhancement in a horizontal tube due to the insertion of an adiabatic plate. Special attention is placed on the effects of the eccentricity and tilted angle of the inserted plate on the heat transfer enhancement. The governing equations are first transformed into curvilinear coordinates, then discretized into the finite difference form through the finite-volume method. It is found that the greater the eccentricity, the smaller the pressure drop, and the worse the heat transfer effect. Also, the optimum position of the inserted plate is found to be at the center of the tube.
๐ SIMILAR VOLUMES
## Abstract This study conducts numerical analyses and experiments on natural convection heat transfer in eccentric horizontal annuli between a heated outer tube and a cooled inner tube with different orientations. The outer tube is an elliptical tube, and the inner tube is a cylindrical tube. Expe
In this study, experimental and three-dimensional numerical studies were performed to investigate the effects of plate spacing and temperature difference on natural convection between isothermally heated upward-facing lower horizontal plate and externally insulated horizontal upper plate. Air is use
## Abstract A pulsating flow in a pipe was experimentally investigated to determine the effect of pulsation on the rate of heat transfer. The influence of hydrodynamic parameters and characteristics of the pulsation on heat transfer was carefully studied. In order to adjust the pulsating parameters
Two-dimensional (2-D) laminar flow and heat transfer through an array of parallel flat plates with finite thickness was studied numerically. A computer program based on the bounded skew hybrid differencing (BSHD) scheme was used and validated to determine the recirculation length, friction factor, a