## Abstract Cardiac pulsatility causes a nonrigid motion of the brain. In multi‐shot diffusion imaging this leads to spatially varying phase changes that must be corrected. A conjugate gradient based reconstruction is presented that includes phase changes measured using two‐dimensional navigator ec
Nonlinear phase correction for navigated diffusion imaging
✍ Scribed by Karla L. Miller; John M. Pauly
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 908 KB
- Volume
- 50
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Motion during diffusion‐weighted imaging (DWI) introduces phase errors that can cause significant artifacts in brain images. One method of correcting these errors uses additional navigator data to measure the phase corruptions. Standard navigator methods correct for rigid‐body motion but cannot correct for nonrigid deformations of the brain related to the cardiac cycle. This work derives a generalized reconstruction that corrects for nonrigid motion based on a least‐squares formulation. Since this reconstruction has the disadvantage of being computationally expensive, an approximation is presented, called a refocusing reconstruction. The refocusing reconstruction is both efficient and straightforward. Each readout is multiplied in image space by the phase conjugate of the navigator image, and these rephased readouts are then summed. The conditions under which the refocusing reconstruction is sufficient are considered and methods to improve the quality of refocused images are discussed. In particular, synchronization of the acquisition to the cardiac cycle can provide data that is well‐conditioned to the refocusing reconstruction without incurring the large time penalty traditionally associated with cardiac gating. These methods are applied to steady‐state DWI, a promising pulse sequence that is particularly sensitive to motion‐induced phase artifacts. The refocusing reconstruction is shown to significantly improve SS‐DWI over standard rigid‐body corrections. Magn Reson Med 50:343–353, 2003. © 2003 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract This article describes the first application of true online motion correction to diffusion‐weighted RARE imaging. Two orthogonal navigator echoes were acquired and zeroth and first‐order phase corrections applied in less than 8 ms between a diffusion‐weighted magnetization preparation a
## Abstract Single‐shot techniques have preferentially been adopted for diffusion‐weighted imaging due to their reduced sensitivity to bulk motion. However, the limited spatial resolution achievable results in orientational signal averaging within voxels containing a distribution of fibers. This le
## Abstract In this paper, a series of diffusion‐weighted fast spin‐echo (FSE) sequences with a new motion correction scheme are introduced. This correction scheme is based on the navigator echo technique. Unlike conventional spin‐echo imaging, motion correction for FSE is complicated by the phase
## Abstract ## Purpose To correct for displacement artifacts in 3D phase contrast imaging. ## Materials and Methods A 3D phase contrast pulse sequence was modified so that displacements of velocity measurements were restricted to one direction. By applying a postprocessing method, displaced meas