## Abstract ## Purpose To evaluate three‐dimensional (3D), free‐breathing, steady‐state free precession (SSFP) magnetic resonance angiography (MRA) for volumetric assessment of ventricular function. ## Materials and Methods In 18 subjects (mean age = 21.5 years) 3D datasets of the heart and grea
Noncontrast SSFP pulmonary vein magnetic resonance angiography: Impact of off-resonance and flow
✍ Scribed by Peng Hu; Christian T. Stoeck; Jouke Smink; Dana C. Peters; Long Ngo; Beth Goddu; Kraig V. Kissinger; Lois A. Goepfert; Jonathan Chan; Thomas H. Hauser; Neil M. Rofsky; Warren J. Manning; Reza Nezafat
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 519 KB
- Volume
- 32
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To investigate pulmonary vein (PV) off‐resonance and blood flow as causes of signal void artifacts in noncontrast steady‐state‐free‐precession (SSFP) PV magnetic resonance angiography (MRA).
Materials and Methods
PV blood off‐resonance was measured on 11 healthy adult subjects and 10 atrial fibrillation (AF) patients. Noncontrast PV MRA was performed using a 3D slab‐selective SSFP sequence at 1.5T on seven healthy subjects with signal profile shifts of 0–125 Hz. The time‐resolved blood flow velocity of the PVs was measured on five healthy subjects. The impact of flow was studied on six healthy subjects, on whom SSFP PV MRA was acquired twice with the electrocardiogram (ECG) trigger delay corresponding to low and high flow, respectively.
Results
The PV off‐resonances were 97 ± 27 Hz, 65 ± 20 Hz, 74 ± 25 Hz, and 52 ± 17 Hz for right inferior, left inferior, right superior, and left superior PVs, respectively, on healthy subjects, and 74 ± 20 Hz, 38 ± 9 Hz, 51 ± 20 Hz, and 28 ± 11 Hz on AF patients (P<0.01 for all). The off‐resonance caused severe signal voids in the PVs. Signal acquired during mid‐diastole with high PV flow caused additional signal voids in the left atrium, which was reduced by setting the ECG trigger delay to late‐diastole.
Conclusion
PV off‐resonance and flow causes signal void artifacts in noncontrast 3D slab‐selective SSFP PV MRA. J. Magn. Reson. Imaging 2010;32:1255–1261. © 2010 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To study the effects of field strength and parallel imaging on image contrast and interstudy reproducibility of right and left ventricular (RV and LV) measurements using steady‐state free precession (SSFP) cardiovascular magnetic resonance (CMR). ## Materials and Methods T
## Abstract The purposes of this work were to estimate regional and global pulmonary perfusion and display pulmonary vasculature in 10 postoperative lung transplant patients using breath‐hold, contrast‐enhanced (0.2 mmol/kg, Gd DTPA‐BMA, Omniscan, Nycomed, Inc., Princeton, NJ), three‐dimensional (3
Purpose: To assess the capability of four-dimensional (4D) time-resolved magnetic resonance angiography (MRA) to assess pulmonary arteriovenous malformations (PAVMs) patency by analyzing pulmonary arterial and venous enhancement kinetics. Materials and Methods: Seven patients with eight documented
## Abstract ## Purpose To determine whether pulmonary arterial and venous transit times measured by time‐resolved magnetic resonance angiography (MRA) can be used as a diagnostic tool for pulmonary arterial hypertension (PAH). ## Materials and Methods Twelve patients with confirmed PAH and 10 he
## Abstract The purpose of this study was to investigate the impact of navigator timing on image quality in navigator‐gated and real‐time motion‐corrected, free‐breathing, three‐dimensional (3D) coronary MR angiography (MRA) with submillimeter spatial image resolution. Both phantom and in vivo inve