𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP

✍ Scribed by Tolga Çukur; Jin H. Lee; Neal K. Bangerter; Brian A. Hargreaves; Dwight G. Nishimura


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
303 KB
Volume
61
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Flow‐independent angiography is a non‐contrast‐enhanced technique that can generate vessel contrast even with reduced blood flow in the lower extremities. A method is presented for producing these angiograms with magnetization‐prepared balanced steady‐state free precession (bSSFP). Because bSSFP yields bright fat signal, robust fat suppression is essential for detailed depiction of the vasculature. Therefore, several strategies have been investigated to improve the reliability of fat suppression within short scan times. Phase‐sensitive SSFP can efficiently suppress fat; however, partial volume effects due to fat and water occupying the same voxel can lead to the loss of blood signal. In contrast, alternating repetition time (ATR) SSFP minimizes this loss; however, the level of suppression is compromised by field inhomogeneity. Finally, a new double‐acquisition ATR‐SSFP technique reduces this sensitivity to off‐resonance. In vivo results indicate that the two ATR‐based techniques provide more reliable contrast when partial volume effects are significant. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


3D non-contrast-enhanced MR angiography
✍ Randall B. Stafford; Mohammad Sabati; Houman Mahallati; Richard Frayne 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 227 KB

## Abstract Balanced steady‐state free precession (bSSFP) is capable of producing ample fat‐water separation. In the case of the bSSFP Dixon method, the phase between fat and water can be manipulated by setting repetition time (TR) to an odd‐half‐multiple of the cycle time and adjusting the center

Single-dose time-resolved contrast enhan
✍ Chun-Chieh Wang; Huei-Lung Liang; Chia-Chi Hsiao; Matt Chiung-Yu Chen; To-Ho Wu; 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 340 KB 👁 1 views

## Abstract ## Purpose To prospectively study the diagnostic performance of hybrid single‐dose contrast‐enhanced MRA of peripheral arterial disease (PAD), with digital subtraction angiography (DSA) as the reference standard. ## Materials and Methods Hybrid MRA, combining time resolved imaging of

Contrast-enhanced peripheral MR angiogra
✍ Tim Leiner; Marianne de Vries; Romhild Hoogeveen; G. Boudewijn C. Vasbinder; Eti 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 836 KB

## Abstract ## Purpose To report preliminary experience with contrast‐enhanced magnetic resonance angiography (CE‐MRA) of the peripheral arteries on a 3.0 T whole‐body scanner equipped with a prototype body coil. ## Materials and Methods Four healthy volunteers were imaged on the 3.0 T system an

Accelerating non-contrast-enhanced MR an
✍ Zheng Chang; Qing-San Xiang; Hao Shen; Fang-Fang Yin 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 451 KB

## Abstract ## Purpose: To accelerate non‐contrast‐enhanced MR angiography (MRA) with inflow inversion recovery (IFIR) with a fast imaging method, Skipped Phase Encoding and Edge Deghosting (SPEED). ## Materials and Methods: IFIR imaging uses a preparatory inversion pulse to reduce signals from

Visualization of external carotid artery
✍ Naoe Satogami; Tomohisa Okada; Takashi Koyama; Kimio Gotoh; Toshikazu Kamae; Kao 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 301 KB

## Abstract ## Purpose To evaluate visibility of the external carotid artery (ECA) and its branches using three‐dimensional (3D) balanced steady‐state free‐precession (SSFP) MR angiography with a time‐spatial labeling inversion pulse (Time‐SLIP), and to provide an optimal value of the inversion ti

Measuring aortic diameter with different
✍ Silke Potthast; Lee Mitsumori; Luana A. Stanescu; Michael L. Richardson; Kelley 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 373 KB 👁 1 views

## Abstract ## Purpose: To compare nongated three‐dimensional (3D) contrast‐enhanced magnetic resonance angiography (CE‐MRA) with 3D‐navigated cardiac‐gated steady‐state free‐precession bright blood (3D‐nav SSFP) and noncontrast 2D techniques for ascending aorta dimension measurements. ## Materia