✦ Synopsis


Abstract

Purpose

To evaluate visibility of the external carotid artery (ECA) and its branches using three‐dimensional (3D) balanced steady‐state free‐precession (SSFP) MR angiography with a time‐spatial labeling inversion pulse (Time‐SLIP), and to provide an optimal value of the inversion time (TI).

Materials and Methods

Peripheral‐pulse‐wave‐gated 3D balanced SSFP images were obtained in 20 healthy volunteers. Images with a Time‐SLIP using four different TIs (600, 900, 1200, and 1500 ms) and without a Time‐SLIP, referred to as sequence A to E, were acquired for each subject and compared for visibility scores of ECA system and relative signal intensity (SI) of ECA.

Results

Average Friedman rank for overall visibility was 1.63, 3.01, 3.59, 3.58, and 3.20 for sequence A to E, respectively. Sequence C and D yielded significantly higher visibility than sequence A, B, and E. The mean relative SI value was 0.97, 0.87, 0.81, 0.76, and 0.67 for sequence A to E, respectively.

Conclusion

Balanced SSFP MR angiography with a Time‐SLIP is superior to that without a Time‐SLIP, showing excellent visualization of ECA system in approximately 3 min in average with sufficient background suppression including veins and salivary ducts. A TI of 1200 ms was considered to be optimal for this purpose. J. Magn. Reson. Imaging 2009;30:678–683. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Non-contrast-enhanced MR angiography for
✍ Kotaro Shimada; Hiroyoshi Isoda; Tomohisa Okada; Toshikazu Kamae; Yoji Maetani; 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 393 KB 👁 1 views

## Abstract ## Purpose To selectively visualize the hepatic vein and inferior vena cava (IVC) using three‐dimensional (3D) true steady‐state free‐precession (SSFP) MR angiography with time‐spatial labeling inversion pulse (T‐SLIP), and to optimize the acquisition protocol. ## Materials and Method

Non-contrast-enhanced MR portography wit
✍ Kotaro Shimada; Hiroyoshi Isoda; Tomohisa Okada; Toshikazu Kamae; Shigeki Arizon 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 482 KB

## Abstract ## Purpose To compare and evaluate images acquired with two different MR angiography (MRA) sequences, three‐dimensional (3D) half‐Fourier fast spin‐echo (FSE) and 3D true steady‐state free‐precession (SSFP) combined with two time‐spatial labeling inversion pulses (T‐SLIPs), for selecti