𝔖 Bobbio Scriptorium
✦   LIBER   ✦

New on-line concentrator for LC-GC: Analysis of PAHs with LC-GC

✍ Scribed by Heo, Gwi Suk ;Suh, Jung Kee


Publisher
John Wiley and Sons
Year
1990
Tongue
English
Weight
438 KB
Volume
13
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A new, versatile, and low cost on‐line LC‐GC interface has been devloped for the fast and reliable introduction of large volume samples into a cappillary GC column without using the conventional retention gap. PAHs in soot were analyzed by on‐line normal phase HPLC‐capillary GC. A glass, vial‐shaped on‐line concentrator provides a zone for solvent evaporation and sample concentration. Large volumes of HPLC eluate can be concentrated with the on‐line concentrator and then transferred directly into the cappillary column. Trace levels (< 10 ppb) of PAH compounds can be efficiently concentrated with the on‐line concentrator and determined without loss or contamination.


📜 SIMILAR VOLUMES


High temperature vaporizing chambers for
✍ Boderius, Ulf ;Grob, Konrad ;Biedermann, Maurus 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 652 KB

## Abstract The suitability of some chambers for sample evaporation at high input flow rates (>100 μl/min) was studied by visual experiments. The chambers were at temperatures far above the solvent boiling point in order to achieve the heat transfer required. Shooting liquid owing to violent evapor

On-line LC-GC-AED and LC-GC-MS - multidi
✍ Lewis, Alastair C. ;Askey, Sarah A. ;Holden, Krystyna M. ;Bartle, Keith D. ;Pill 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 608 KB

## Abstract The composition and concentration of polycyclic aromatic compounds (PAC) in fuels. Theier combustion products and in the atmosphere remains a topic of considerable interest. Despite the wealth of literature on the identification of PAC, speciation at low concentrations remains difficult

Separation of metal complexes by on-line
✍ Lukkari, P. ;Hannuksela, J. ;Mattinen, M.-L. ;Virolainen, M. ;Häkkinen, Vera M. 📂 Article 📅 1990 🏛 John Wiley and Sons 🌐 English ⚖ 243 KB

## Abstract The on‐line coupled LC‐GC technique was applied to the analysis of several metal chelates of __N__,__N__‐diethyldithiocarbamic acid. A 10‐port valve interface was used to couple the LC and GC instruments. Conditions during sample transfer into the GC gave fully concurrent solvent evapor

Coupled LC-GC: A new method for the on-l
✍ Barcarolo, Roberto 📂 Article 📅 1990 🏛 John Wiley and Sons 🌐 English ⚖ 407 KB 👁 1 views

## Abstract This paper describes the use of coupled LC‐GC for the determination of organochlorine pesticide residues in fat samples. Organochlorine pesticide residues are preseparated from fat by LC on a short C‐18 column using an organic solvent as the mobile phase. Evaporation of the LC eluent is

Determination of single PCB congeners in
✍ Helena Hyvönen; Tuula Auvinen; Marja-Liisa Riekkola; Kimmo Himberg 📂 Article 📅 1992 🏛 John Wiley and Sons 🌐 English ⚖ 349 KB 👁 1 views

## Abstract An on‐line coupled LC‐GC technique was applied to the analysis of polychlorobiphenyls (PCBs) in Baltic herring. The liquid chromatographic (LC) and gas chromatographic (GC) instruments were coupled with a loop‐type interface and concurrent solvent evaporation was used in transferring th