✦ Synopsis


Abstract

In this article, a new method for measuring a total spectral radiance factor of a FWA‐treated sample illuminated by a specific standard illuminant is introduced. The method replaces an unstable real fluorescent standard by a bi‐spectral luminescent radiance factor data, which works as a virtual fluorescent standard (VFS) by knowing spectral intensity distributions of illuminations applied to the sample. The method utilizes two illuminations I~1~ and I~2~ whose relative spectral intensity distributions are different from each other and synthesizes a virtual illumination presenting the identical fluorescent spectral radiance factor to that presented by the standard illuminant with the VFS of the specific bi‐spectral luminescent radiance factor by linearly combining I~1~ and I~2~ with the suitable weighting factors. The applicability of the method is examined in principle by comparing ISO brightness and CIE whiteness index of fluorescent standard paper as a test sample obtained by this new method to the assigned values. © 2007 Wiley Periodicals, Inc. Col Res Appl, 32, 195–200, 2007


📜 SIMILAR VOLUMES


A rapid, new and direct method for isola
✍ Englert, Edwin ;Wayne, Anthony W. ;Wales, Eugene E. ;Straight, Richard C. 📂 Article 📅 1979 🏛 John Wiley and Sons 🌐 English ⚖ 365 KB

## Abstract Reversed‐phase high performance liquid chromatography on microparticulate columns of octadecylsilane with elution by a gradient of acetonitrile in phosphate buffer, pH 7.5, separated porphyrin free acids directly in urine for the first time. Interfering fluorescence was removed with a p

A new method for the measurement of dyna
✍ Takayuki Murayama 📂 Article 📅 1975 🏛 John Wiley and Sons 🌐 English ⚖ 185 KB 👁 2 views

## Abstract The Rheovibron viscoelastometer is useful for obtaining dynamic __tensile__ mechanical properties of films and fibers over a wide temperature range. Numerous studies of dynamic tensile mechanical properties have been made in the temperature range of −160°C to 250°C in an atmosphere at 0

Validation of a method for the determina
✍ Carmen Gabiola; María A. García-Calonge; María P. Portillo; J. Alfredo Martínez; 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 427 KB 👁 2 views

The validation of a fast, reliable, and specific method for the screening, confirmation, and determination of salbutamol in urine with (total) and without (free fraction) a hydrolysis step was developed. Sample urine from different animal species was extracted using Bond Elut certify columns. The de