New criterion to aid manual and automatic selection of the arterial input function in dynamic susceptibility contrast MRI
✍ Scribed by Egbert J. W. Bleeker; Matthias J. P. van Osch; Alan Connelly; Mark A. van Buchem; Andrew G. Webb; Fernando Calamante
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 420 KB
- Volume
- 65
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Dynamic susceptibility contrast‐MRI requires an arterial input function (AIF) to obtain cerebral blood flow, cerebral blood volume, and mean transit time. The current AIF selection criteria discriminate venous, capillary, and arterial profiles based on shape and timing characteristics of the first passage. Unfortunately, partial volume effects can lead to shape errors in the bolus passage, including a narrower and higher peak, which might be selected as a “correct” AIF. In this study, a new criterion is proposed that detects shape errors based on tracer kinetic principles for computing cerebral blood volume. This criterion uses the ratio of the steady‐state value to the area‐under‐the‐curve of the first passage, which should result in an equal value for tissue and arterial responses. By using a reference value from tissue, partial volume effects–induced shape errors of the AIF measurement can be detected. Different factors affecting the ratio were investigated using simulations. These showed that the new criterion should only be used in studies with T~1~‐insensitive acquisition. In vivo data were used to evaluate the proposed approach. The data showed that the new criterion enables detection of shape errors, although false positives do occur, which could be easily avoided when combined with current AIF selection criteria. Magn Reson Med, 2011. © 2010 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
To prevent systematic errors in quantitative brain perfusion studies using dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI), a reliable determination of the arterial input function (AIF) is essential. We propose a novel algorithm for correcting distortions of the AIF cau
## Abstract One of the most powerful features of the dynamic contrast‐enhanced (DCE) MRI technique is its capability to quantitatively measure the physiological or pathophysiological environments assessed by the passage of contrast agent by means of model‐based pharmacokinetic analysis. The widely
The arterial input function is crucial in pharmacokinetic analysis of dynamic contrast-enhanced MRI data. Among other artifacts in arterial input function quantification, the blood inflow effect and nonideal radiofrequency spoiling can induce large measurement errors with subsequent reduction of acc
Gd-DTPA kinetics in arterial blood was investigated by dynamic MRI in 47 patients with malignant and benign mammary tumors. Signal enhancement was monitored for 10 min after the beginning of a 1-min infusion of 0.1 mmol/kg Gd-DTPA. Kinetics in blood was biexponential with median half-lives of 21 sec