𝔖 Bobbio Scriptorium
✦   LIBER   ✦

New criteria for assessing fit quality in dynamic contrast-enhanced T1-weighted MRI for perfusion and permeability imaging

✍ Scribed by Daniel Balvay; Frédérique Frouin; Guillaume Calmon; Bertrand Bessoud; Edmond Kahn; Nathalie Siauve; Olivier Clément; Charles A. Cuenod


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
688 KB
Volume
54
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Contrast‐enhanced (CE) MRI provides in vivo physiological information that cannot be obtained by conventional imaging methods. This information is generally extracted by using models to represent the circulation of contrast agent in the body. However, the results depend on the quality of the fit obtained with the chosen model. Therefore, one must check the fit quality to avoid working on physiologically irrelevant parameters. In this study two dimensionless criteria—the fraction of modeling information (FMI) and the fraction of residual information (FRI)—are proposed to identify errors caused by poor fit. These are compared with more conventional criteria, namely the quadratic error and the correlation coefficient, both theoretically and with the use of simulated and real CE‐MRI data. The results indicate the superiority of the new criteria. It is also shown that these new criteria can be used to detect oversimplified models. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Precision in measurements of perfusion a
✍ Lucy E. Kershaw; David L. Buckley 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 286 KB

## Abstract Dynamic contrast‐enhanced MRI is used to estimate microvascular parameters by tracer kinetics analysis. The time for the contrast agent to travel from the artery to the tissue of interest (bolus arrival time (BAT)) is an important parameter that must be measured in such studies because

New algorithm for quantifying vascular c
✍ E. Mark Haacke; Cristina L. Filleti; Ramtilak Gattu; Carlo Ciulla; Areen Al-Bash 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 247 KB

## Abstract In this work, we present a new method for predicting changes in tumor vascularity using only one flip angle in dynamic contrast‐enhanced (DCE) imaging. The usual DCE approach finds the tissue initial __T__~1~ value __T__~1~(0) prior to injection of a contrast agent. We propose finding c

Application of breath-hold T2-weighted,
✍ Sang Il Choi; Chun Zi Jiang; Keun Ho Lim; Sang Tae Kim; Chung Hwan Lim; Gyung Yu 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 346 KB 👁 2 views

The purpose of this study was to correlate the abnormal signal area on various magnetic resonance (MR) images to the infarct area on pathologic examination and to assess the myocardial viability on the basis of MR images. T2weighted, first-pass perfusion, and delayed gadolinium-enhanced T1-weighted