C-peptide is secreted in equimolar concentrations with insulin, and is often measured to assess pancreatic Ξ²-cell function. C-peptide analysis is most often performed by radioimmunoassay (RIA) which has several disadvantages. We evaluated an automated, chemiluminescent immunoassay for C-peptide in t
New automated chemiluminescent assay for erythropoietin
β Scribed by Elizabeth W. Benson; Robert Hardy; Carolyn Chaffin; C. Andrew Robinson; Robert J. Konrad
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 37 KB
- Volume
- 14
- Category
- Article
- ISSN
- 0887-8013
No coin nor oath required. For personal study only.
β¦ Synopsis
Erythropoietin (EPO) is a polypeptide hormone produced by the kidney that regulates erythropoiesis by controlling the proliferation and differentiation of erythroid progenitors in bone marrow. Assays for EPO are used to monitor dosage and response to human recombinant erythropoietin also may have diagnostic utility in the differential diagnosis of anemia and polycythemia. We evaluated an automated, chemiluminescent immunoassay for EPO (DPC Immulite) in terms of precision, linearity, interference, and correlation with reference assays. The Immulite assay demonstrated acceptable correlation with the reference immunochemiluminometric method (slope = 1.087, y intercept = 0.567, R value = 0.990). Within-run CVs ranged from 2.3% to 5.0%, while between-run CVs ranged from 4.1% to 9.5%. Linearity extended beyond the manufacturer's stated claims, and recovery ranged from 96.8% to 100.9% across the concentrations tested. No significant interference was noted with hemoglobin, bilirubin, or triglyceride. Overall, this method compares favorably with the existing immunochemiluminometric reference method and offers clinical laboratories an alternative for the analysis of erythropoietin.
π SIMILAR VOLUMES
## Abstract Measuring low amounts of antiβerythropoietin antibodies (antiβEPO Abs) is important to evaluate the therapeutic safety of recombinant human erythropoietin (rhEPO). In this work, a simple, sensitive and highβthroughput chemiluminescent (CL) imaging assay was developed for the detection o
A luminol-dependent chemiluminescence assay for the assessment of the phagocytosis of erythrocytes sensitized w i t h anti-D IgG immunoglobulin by mononuclear leukocytes is described. The mononuclear leukocytes were obtained by apheresis enriched by centrifugation through a density gradient and stor
Acetylcholine and choline chemiluminescent assays have limitations when these compounds are detected in small areas of mammalian nervous tissue. Use of 7-dimethylaminonaphthalene-1.2-dicarbonic acid hydrazide (7-DMAN), instead of luminol, gives a threefold increase in emitted light in the chemilumin