𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Neutral-carrier-based ion-selective electrodes

✍ Scribed by P. Oggenfuss; W.E. Morf; U. Oesch; D. Ammann; E. Pretsch; W. Simon


Publisher
Elsevier Science
Year
1986
Tongue
English
Weight
703 KB
Volume
180
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


Neutral-carrier-based ion-selective electrodes for the assay of alkali and alkaline earth metal cations have advanced to become the most frequently used potentiometric sensors in clinical chemistry . The major developments since the realization of the first potentiometric cell assemblies utilizing electrically neutral complexing agents (valinomycin and the macrotetrolides) in 1966 are presented .


πŸ“œ SIMILAR VOLUMES


Catalysis of Ion Transfer by Tetraphenyl
✍ Peter Gehrig; Werner E. Morf; Martin Welti; ErnΓΆ Pretsch; Wilhelm Simon πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 German βš– 501 KB

## Abstract For certain ionophores of extremely high lipophilicity, kinetic limitations of the carrier‐induced ion transfer between aqueous and membrane phase may heavily disturb the electromotive behaviour of the ion‐selective membrane electrode. These limitations may be overcome by adding tetraph

Cation-Response Mechanism of Neutral Car
✍ Werner E. Morf; Wilhelm Simon πŸ“‚ Article πŸ“… 1986 πŸ› John Wiley and Sons 🌐 German βš– 696 KB

Results of voltammetric, potentiometric, chronoamperometric, ion transport, and extraction studies on neutral carrier based, plasticized polyfvinyl chloride) membranes are summarized. They unambiguously confirm that such bulk membranes dispose of immobile anionic sites. These fixed sites lead to a D

All Solid State Hydrogen Ion Selective E
✍ Won-Sik Han; Myon-Yong Park; Koo-Chun Chung; Dong-Hoe Cho; Tae-Kee Hong πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 91 KB πŸ‘ 1 views

Hydrogen ion selective solid contact electrode based on tribenzylamine have shown the best Nernstian slope, selectivity and the widest response range in Tris buffered pH sample solutions. Their linear dynamic range was pH 2.48-11.21 and Nernstian slope showed 55.1 mV=pH (at 20 AE 0.2 C). When it was

Al(III)–Selective Electrode Based on Fur
✍ M. F. Mousavi; M. Arvand-Barmchi; M. A. Zanjanchi πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 68 KB πŸ‘ 1 views

A PVC membrane electrode for aluminum(III) ions based on Furil (ethan dione, di-(2-furyl)) as neutral carrier was prepared. The electrode exhibits a near Nernstian response for Al 3ΓΎ ions over a wide concentration range (1.0610 76 to 1.0610 72 mol dm 73 ) with a limit of detection 1.3610 77 mol dm 7

Chloride-selective electrodes based on m
✍ Markus Rothmaier; Wilhelm Simon πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 621 KB

Mercury organic compounds incorporated m solvent polymeric membranes act as neutral tamers for chlonde In sharp contrast to classical anion exchangers, membranes contammg (~-[4,5-dlmethyl-3,6-bIs(octyloxy)-1,2-phenyleneDb&tnfluoroacetato-O&mercury (ETH 9009) or tetrak&\_(dunethyl sulphoxlde-0 O)lbls