Nano-liquid chromatography—direct electron ionization mass spectrometry: improving performance by a new ion source adapter

✍ Scribed by Cornelia Flender; Christian Wolf; Peter Leonhard; Michael Karas


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
294 KB
Volume
46
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


A novel interface adapter has been designed to provide a new way of directly coupling a nano‐liquid chromatograph to an electron ionization mass spectrometer. It connects the transfer capillary coming from the liquid chromatograph to the ionization chamber and can be easily screwed into the ion source. Liquid coming from the column passes through the heated adapter flow path and is vaporized. A continuous flow of new liquid pushes the vapor into the ionization chamber where it is ionized and continues on to the mass analyzer. The advantages of the new adapter are reduced ice formation inside the ion source and less clogging of the transfer capillary. Improvements achieved are demonstrated on the basis of caffeine and steroid analysis. The limits of detection of selected steroids are compared with and without the adapter. The adapter improves the detection limit of the system by a factor of 2 and precision from ≤15% to ≤9% relative standard deviation. No derivatization procedure is necessary before the analysis of small polar compounds. The resulting spectra are reproducible, easily interpretable, and database searchable. The new method is robust, delivers reproducible results, and provides a highly efficient alternative to existing methods in the field of pharmaceutical analysis. Copyright © 2011 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Liquid chromatography-electron ionizatio
✍ Achille Cappiello; Giorgio Famiglini; Pierangela Palma; Antonella Siviero 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 291 KB

## Abstract A comprehensive evaluation and a thorough discussion of the fields of possible applications of the Direct‐EI interface are described in this review. Direct‐EI allows the direct introduction of the effluent from a capillary HPLC column into the electron ionization (EI) ion source of a ma

Detection of corticosteroids by high-per
✍ S. M. R. Stanley; B. S. Wilhelmi; J. P. Rodgers; A. Guthrie 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 539 KB

A normal-phase high-performance liquid chromatographic/particle beam mass spectrometric (negative chemical ionization) method has been developed for the detection of Synthetic corticosteroids (SC). Characteristic and reproducible full-scan spectra were obtained for the SC analysed. The limit of dete

Analysis of a commercial preparation of
✍ Chien-Chen Lai; Pei-Lun Tsai; Cheng Yu; Guor-Rong Her 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 114 KB 👁 3 views

Because of the lack of a UV chromophore and their much smaller abundances in comparison with the major component, the minor components in erythromycin estolate preparations are difficult to analyze by high performance liquid chromatography ultraviolet (HPLC-UV). Tentative assignment of the major and

Identification and characterization by h
✍ A. Motos Gallardo; J. A. Hernández; J. M. Hernández; J. M. Rovira; L. Fluvià; A. 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 171 KB

## Abstract This work illustrates the practical use of combined microbore reversed‐phase high‐performance liquid chromatography (RP‐HPLC) with electrospray ionization mass spectrometry (ESI‐MS) in protein identification. The approach consisted of the detection of the abnormal β‐globin chain by ESI‐