Analytical techniques for the detection of small amounts of explosives (in the picogram range) are now involved in various application. Some of them concern soil, water and air monitoring in order to face environmental problems related to improper handling procedures either in stocking or in wasting
Mutation scanning by ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry (ICEMS)
✍ Scribed by Herbert Oberacher; Christian G. Huber; Peter J. Oefner
- Publisher
- John Wiley and Sons
- Year
- 2002
- Tongue
- English
- Weight
- 496 KB
- Volume
- 21
- Category
- Article
- ISSN
- 1059-7794
No coin nor oath required. For personal study only.
✦ Synopsis
Partially denaturing high-performance liquid chromatography has emerged as the most sensitive physical mutation scanning method. However, there are a few reports of mutations missed or only detectable at unique temperatures. The combined use of ion-pair reversed-phase high-performance liquid chromatography under completely denaturing conditions and electrospray ionization quadrupole ion trap mass spectrometry (ICEMS) obviates the need for selecting appropriate temperatures for resolving heteroduplices and allows the discrimination of different alleles even when they co-elute due to distinct mass differences between nucleobases. This was demonstrated for the detection of four mutations (259G>A, 286A>G, 300T>G, and 331+1G>A) in exon 5 and intron 5 of BRCA1, respectively. Current mass resolution of quadrupole ion trap mass spectrometers limits the identification of single A>T or T>A transversions with a mass difference of 9 Da to fragments <80 base pairs (bp). The presence of all other mutations can be detected in fragments up to approximately 105 bp. The approach may prove particularly useful in the mutational scanning of AT- or GC-rich sequences that are recalcitrant to most other methods.
📜 SIMILAR VOLUMES
Analysis of allelic imbalance is of great importance for understanding tumorigenesis and the clinical management of malignant disease. Fluorescent-based capillary electrophoresis (CE) of highly polymorphic short tandem repeats (STRs) has become the main method used to detect the loss/gain of alleles
Disaccharides and linear oligosaccharides were labeled with p-aminobenzoic ethyl ester (ABEE) chromophore and analyzed by negative ion electrospray ionization mass spectrometry (ESIMS). The formation of glycosylamines rather than reductive amination in the labeling reaction produced many characteris
Two complementary approaches utilizing reverse-phase high-performance liquid chromatography and liquid chromatography/mass spectrometry were developed to analyze recombinantly produced Group I and Group II human ADP-ribosylation factors (ARFs). We observe that the NH2 termini of Group II ARFs (ARF4
## Abstract A rapid, sensitive and specific high‐performance liquid chromatography–electrospray ionization mass spectrometry (LC‐ESI‐MS) method has been developed and validated for the determination of oxatomide in human plasma. Flunarizine hydrochloride was employed as the internal standard (IS).