𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Multipurpose NMR imaging using stimulated echoes

✍ Scribed by D. Matthaei; J. Frahm; A. Haase; K. D. Merboldt; W. Hänicke


Publisher
John Wiley and Sons
Year
1986
Tongue
English
Weight
614 KB
Volume
3
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


STEAM (stimulated-echo acquisition mode) imaging techniques recently introduced by the authors are demonstrated to provide a versatile tool for improving the parametric specificity in NMR imaging. Stimulated echoes can be excited by a sequence of at least three rf pulses with flip angles of 90 degrees or less. The main characteristics of the STEAM method are based on the great functional flexibility of an imaging sequence comprising three rf pulses unequal to 180 degrees and three intervals prior to acquisition of the data. Major advantages are the easy access to contiguous multiplanar images, to CHESS (chemical-shift-selective) images, and to T1 information. Moreover, the rf power deposition is considerably reduced as compared to spin-echo NMR imaging sequences. Here first in vivo results on human extremities are presented including contiguous multislice images, multiple CHESS images, and spin-lattice relaxation time images calculated from a series of simultaneously recorded T1-weighted STEAM images.


📜 SIMILAR VOLUMES


Localized imaging using stimulated echoe
✍ Pamela Mills; Wil Chew; Lawrence Litt; Michael Moseley 📂 Article 📅 1987 🏛 John Wiley and Sons 🌐 English ⚖ 387 KB

Stimulated-echo localized spectroscopy was combined with phase-and frequency-encoding gradients to obtain "zoom" or magnified images of specific organs in situ. The technique requires neither surface coils nor an imaging coil arrangement that exclusively isolates the target organ. This technique can

Diffusion imaging using stimulated echoe
✍ Klaus-Dietmar Merboldt; Wolfgang Hänicke; Jens Frahm 📂 Article 📅 1991 🏛 John Wiley and Sons 🌐 English ⚖ 454 KB

The application of stimulated echo acquisition mode (STEAM) sequences for NMR imaging of diffusion is especially suited for spins with T1 much greater than T2 as, e.g., encountered in proton NMR studies of biological systems. Molecular self-diffusion coefficients may be calculated from a set of diff

Velocity imaging of slow coherent flows
✍ A. Caprihan; R. H. Griffey; E. Fukushima 📂 Article 📅 1990 🏛 John Wiley and Sons 🌐 English ⚖ 480 KB

## Abstract We measure the velocity distribution of slow fluid flow in model systems using stimulated echoes and velocity phase encoding. We show velocity images of slow coherent flow with velocities of the order of 0.1 mm/s which is slower than can be obtained by the bolus‐tracking method. The edd

Projection flow imaging by bolus trackin
✍ Thomas K. F. Foo; William H. Perman; Colin S. O. Poon; Jack T. Cusma; John C. Sa 📂 Article 📅 1989 🏛 John Wiley and Sons 🌐 English ⚖ 1010 KB

Previous investigators have employed the concept of bolus tracking using either spin echoes or gradient echoes. In this paper we introduce two methods ofbolus tracking using planar-and volume-selective stimulated echoes. The planar method employs a selective 90" rf pulse which tags all spins in a pa