𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Diffusion imaging using stimulated echoes

✍ Scribed by Klaus-Dietmar Merboldt; Wolfgang Hänicke; Jens Frahm


Publisher
John Wiley and Sons
Year
1991
Tongue
English
Weight
454 KB
Volume
19
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


The application of stimulated echo acquisition mode (STEAM) sequences for NMR imaging of diffusion is especially suited for spins with T1 much greater than T2 as, e.g., encountered in proton NMR studies of biological systems. Molecular self-diffusion coefficients may be calculated from a set of diffusion-weighted images acquired with different gradient strengths. A variation of the diffusion time allows the determination of restricted and/or anisotropic diffusion in cellular systems ranging from plants to humans. Problems associated with the presence of unavoidable macroscopic motions in vivo are demonstrated in diffusion studies of human brain. Motion ghosting in diffusion-weighted images may be overcome by means of a high-speed STEAM sequence yielding single-shot images within subsecond acquisition times.


📜 SIMILAR VOLUMES


MR imaging of anisotropic and restricted
✍ Christopher H. Sotak; Limin Li 📂 Article 📅 1992 🏛 John Wiley and Sons 🌐 English ⚖ 696 KB

## Abstract A new magnetic resonance imaging technique for evaluating anisotropic and restricted diffusion effects in a single experiment is described. The method is based on a pulse sequence that simultaneously excites a spin echo (SE) and a stimulated echo (STE) and contains two pairs of diffusio

Echoplanar diffusion tensor imaging of t
✍ G. Steidle; F. Schick 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 570 KB

## Abstract A sequence for echoplanar diffusion tensor imaging of musculature was developed using a stimulated echo preparation. The strategy was optimized in order to obtain reliable diffusion tensor data in a short measuring time. Image distortion problems due to eddy currents arising from long‐l

High-resolution DTI of a localized volum
✍ Eun-Kee Jeong; Seong-Eun Kim; Eugene G. Kholmovski; Dennis L. Parker 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 719 KB

## Abstract Diffusion tensor MRI (DTI) using conventional single‐shot (SS) 2D diffusion‐weighted (DW)‐EPI is subject to severe susceptibility artifacts. Multishot DW imaging (DWI) techniques can reduce these distortions, but they generally suffer from artifacts caused by motion‐induced phase errors

Localized imaging using stimulated echoe
✍ Pamela Mills; Wil Chew; Lawrence Litt; Michael Moseley 📂 Article 📅 1987 🏛 John Wiley and Sons 🌐 English ⚖ 387 KB

Stimulated-echo localized spectroscopy was combined with phase-and frequency-encoding gradients to obtain "zoom" or magnified images of specific organs in situ. The technique requires neither surface coils nor an imaging coil arrangement that exclusively isolates the target organ. This technique can