The ion optics of multi-turn time-of-Ñight (TOF) mass spectrometry was investigated. Two feasible systems using toroidal sector plus quadrupole lenses and cylindrical sectors plus quadrupole doublets were found. The combination of a linear TOF with a Ðgure-of-eight type multi-turn system is proposed
Multi-turn time-of-flight mass spectrometers with electrostatic sectors
✍ Scribed by Michisato Toyoda; Daisuke Okumura; Morio Ishihara; Itsuo Katakuse
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 978 KB
- Volume
- 38
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.546
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The mass resolution of a time‐of‐flight (TOF) mass spectrometer is directly proportional to its total flight pathlength. Multi‐turn or multi‐passage ion optical geometries are necessary to obtain fight distances of sufficient length within reasonable size limitations. We have investigated ion optics for a multi‐turn TOF mass spectrometer with electrostatic sectors. The concept of ‘perfect’ focusing conditions is introduced. Furthermore, a new type of multi‐turn TOF mass spectrometer, the MULTUM Linear plus, was developed. It consists of four cylindrical electric sectors and 28 electric quadrupole lenses. It has a vacuum chamber 60 × 70 × 20 cm in size. Mass resolution is demonstrated to increase according to the number of ion cycles. A mass resolution of 350 000 (m/z = 28, FWHM) was achieved after 501.5 cycles. The MULTUM Linear plus analyzer is not simple, however; 28 electric quadrupole lenses are used. In order to reduce the number of ion optical parts, an improved multi‐turn TOF mass spectrometer, the MULTUM II, consisting of only four toroidal electric sectors, was also developed. The possibility of tandem mass spectrometric applications using multi‐turn TOF mass spectrometers is also discussed. Copyright © 2003 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
A new type of multi-turn time-of-flight mass spectrometer was constructed, consisting of four cylindrical electric sectors and 28 electric quadrupole lenses, the size of the vacuum chamber being 60 × 70 × 20 cm. It was demonstrated that the mass resolution can be increased according to the number of
## Abstract A new multi‐turn ion optical system ‘IRIS’ has been designed for use with a high‐performance time‐of‐flight (TOF) mass spectrometer, which satisfies the new design concepts of time focusing and phase space stability. It has an elliptical flight path composed of four toroidal electric se
High-energy collision-induced dissociation of phosphopeptides using a multi-turn tandem time-of-flight mass spectrometer 'MULTUM-TOF/TOF' A multi-turn tandem time-of-flight mass spectrometer (MULTUM-TOF/TOF) has been designed and constructed at Osaka University. 1,2 The MULTUM-TOF/TOF consists of a
## Abstract Improved resolution for a miniaturized instrument is demonstrated at high masses using a pulsed extraction, 3^″^ linear time‐of‐flight (TOF) mass analyzer. This illustrates the utility of a small and simple mass spectrometer for biological/medical analyses. Current and future applicatio