The ion optics of multi-turn time-of-Ñight (TOF) mass spectrometry was investigated. Two feasible systems using toroidal sector plus quadrupole lenses and cylindrical sectors plus quadrupole doublets were found. The combination of a linear TOF with a Ðgure-of-eight type multi-turn system is proposed
Design of a new multi-turn ion optical system ‘IRIS’ for a time-of-flight mass spectrometer
✍ Scribed by Masaru Nishiguchi; Yoshihiro Ueno; Michisato Toyoda; Mitsutoshi Setou
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 350 KB
- Volume
- 44
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.1531
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A new multi‐turn ion optical system ‘IRIS’ has been designed for use with a high‐performance time‐of‐flight (TOF) mass spectrometer, which satisfies the new design concepts of time focusing and phase space stability. It has an elliptical flight path composed of four toroidal electric sectors, with a flight path length for one lap of 0.974 m. Dimensions and voltages of sector electrodes have been optimized to satisfy theoretical requirements by simulations using surface charge method. Generally, multi‐turn instruments require an injection and ejection system to inject and eject ions. On the basis of this ion optical study, we have designed an injection and ejection ion optical system, which achieves time focusing for the total system. Furthermore, we have designed novel field‐adjusting electrodes (FAEs) for the perforated sectors in the injection and ejection systems, which accurately correct the electric potential around the perforated sector's hole. We have also used simulations to evaluate mass resolving power and ion transmissions for various lap numbers or flight path lengths. Through these we have confirmed that mass resolving powers of over 100 000 can be achieved with reasonable ion transmissions for a given set of initial conditions. Usually a multi‐turn TOF mass spectrometer with a closed optic axis has mass range limitations from overtaking ions. To solve this problem, a TOF segmentation method is proposed that identifies all peaks in a TOF spectrum, including those from overtaking ions. Copyright © 2008 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
A new type of multi-turn time-of-flight mass spectrometer was constructed, consisting of four cylindrical electric sectors and 28 electric quadrupole lenses, the size of the vacuum chamber being 60 × 70 × 20 cm. It was demonstrated that the mass resolution can be increased according to the number of
A new focused ion beam optical system that uses a liquid metal ion source was designed for a new secondary ion time-of-flight mass spectrometry instrument. This optical system consists mainly of two electrostatic lenses. The axial performance of the system was calculated to decide the design values