𝔖 Bobbio Scriptorium
✦   LIBER   ✦

MRI of the intracerebral lesions at 0.5 Tesla: Comparison of fast spin-echo and conventional spin-echo sequences

✍ Scribed by Lutfi Incesu; Mustafa Güneş; Hüseyin Akan; Mustafa Bekir Selçuk


Publisher
Elsevier Science
Year
1996
Tongue
English
Weight
732 KB
Volume
20
Category
Article
ISSN
0895-6111

No coin nor oath required. For personal study only.

✦ Synopsis


Fast spin-echo sequences was compared with conventional spin-echo sequences at 0.5 Tesla, in 130 patients who attended for routine brain MRI. Artefacts and contrast behaviour of anatomical structures and lesions were assessed visually and quantitatively by contrast-to-noise ratios. The difference between conventional spin-echo and fast spin-echo in contrast in intracerebral tumors and infarcts was not found to be significant statistically. Small amounts of haemosiderin and calcifications could not be seen on fast spin-echo images especially in T2 weighted. Flow artefacts were considerably reduced on fast spin-echo images. Motion artefact was considerably increased on dual-echo fast spin-echo sequences. There were no statistical differences between the results of the visual findings and between those of CNR values except for contrast between CSF and white matter and between haemoatoma and background in T2 sequences. Our results suggest that by virtue of the shorter acquisition time, diagnostic reliability and reduced flow artefact single-echo FSE sequences should be preferred to dual-echo CSE sequences in routine brain MRI at 0.5 Tesla.


📜 SIMILAR VOLUMES


MRI in characterization of focal liver l
✍ Andrea Giovagnoni; Enrico Paci; Gianluca Valeri; Paola Ercolani; Rosaria Gesuita 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 782 KB

## Abstract Forty‐one patients with 61 proved focal liver lesions underwent MRI of the liver at 1.0 T, with the aim of evaluating the usefulness of turbo spin‐echo (TSE) sequences in characterizing focal liver lesions, by comparing them with conventional spin‐echo (CSE) sequences. Two different TSE

T2-weighted MRI of rectosigmoid carcinom
✍ Shuhei Yamashita; Takayuki Masui; Motoyuki Katayama; Kimihiko Sato; Nobuko Yoshi 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 278 KB

## Abstract ## Purpose To compare the abilities of T2‐weighted (T2W) imaging using respiratory‐triggered fast spin‐echo (RT‐FSE), breathhold fast‐recovery FSE (BH‐FRFSE), and BH single‐shot FSE (BH‐SSFSE) sequences without an endorectal coil to detect rectosigmoid carcinomas. ## Materials and Met

A comparison of conventional spin-echo a
✍ Wayne B. Patola; Bruce A. Coulter; Patricia M. Chipperfield; Sattam S. Lingawi 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 389 KB

## Abstract Fast spin‐echo (FSE) pulse sequences enable T2‐weighted imaging in a fraction of the time required for T2‐weighted conventional spin‐echo (CSE) imaging. Due to concerns that the altered contrast characteristics of FSE may interfere with the visualization of multiple sclerosis (MS) lesio

T2-weighted MRI of the female pelvis: Co
✍ Takayuki Masui; Motoyuki Katayama; Shigeru Kobayashi; Harumi Sakahara; Tatsuhiko 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 441 KB

## Abstract In 49 patients who had pelvic abnormalities, breath‐hold T2‐weighted fast‐recovery (FR)‐fast spin‐echo (FSE) (imaging time = 24 sec) and nonbreath‐hold FSE MR images (2 min 8 sec) were compared qualitatively (on a four‐point scale) and quantitatively (using signal‐to‐noise ratios (SNRs)

Fat-suppressed T2-weighted MRI of the li
✍ Motoyuki Katayama; Takayuki Masui; Shigeru Kobayashi; Tatsuhiko Ito; Mamoru Taka 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 581 KB

## Abstract The purpose of our study was to compare the value of respiratory‐triggered fast spin‐echo, breath‐hold single‐shot fast spin‐echo, and breath‐hold fast‐recovery fast spin‐echo sequences in detecting hepatic lesions. Fat‐suppressed T2‐weighted magnetic resonance (MR) images obtained with

Comparison of breath-hold multishot echo
✍ Koichiro Yamakado; Hajime Sakuma; Shuichi Murashima; Atsuhiro Nakatsuka; Kaname 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 777 KB

## Abstract The purpose of this study was to evaluate the usefulness of multishot echo‐planar imaging in detecting liver tumors in comparison with respiratory triggered T2‐weighted fast‐spin‐echo (FSE) imaging. Thirty‐two patients with 70 focal liver lesions were imaged using a 1.5‐T high speed MR