Abstract

The purpose of this study was to test the utility of MR thermometry for monitoring the temperature rise on the brain surface and in the scalp induced by skull heating during ultrasound exposures. Eleven locations in three pigs were targeted with unfocused ultrasound exposures (frequency = 690 kHz; acoustic power = 8.2–16.5 W; duration = 20 s). MR thermometry (a chemical shift technique) showed an average temperature rise in vivo of 2.8°C ± 0.6°C and 4.4°C ± 1.4°C on the brain surface and scalp, respectively, at an acoustic power level of 10 W. The temperature rise on the scalp agreed with that measured with a thermocouple probe inserted adjacent to the skull (average temperature rise = 4.6°C ± 1.0°C). Characterization of the transducer showed that the average acoustic intensity was 1.3 W/cm^2^ at an acoustic power of 10 W. The ability to monitor the temperature rise next to the skull with MRI‐based thermometry, as shown here, will allow for safety monitoring during clinical trials of transcranial focused ultrasound. Magn Reson Med 51:1061–1065, 2004. © 2004 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


MRI and contrast-enhanced ultrasound mon
✍ Hai-Ling Margaret Cheng; Masoom A. Haider; Marcus J. Dill-Macky; Joan M. Sweet; 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 855 KB

## Abstract ## Purpose To compare the value of diffusion‐weighted MRI (DWI), dynamic contrast‐enhanced (DCE) MRI, and microbubble contrast‐enhanced ultrasound (CEUS) for assessment of the thermal lesion created by interstitial microwave heating of the normal canine prostate. ## Materials and Meth

Further observations on the measurement
✍ I. R. Young; J. W. Hand; A. Oatridge; M. V. Prior; G. R. Forse 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 485 KB 👁 1 views

## Abstract Previous results for the measurement of __T__~1~ as a means of monitoring temperature have demonstrated a linear calibration with a coefficient of the order of 1.5%C. We have studied the changes in __T__~1~, further, and observe that changes in tissue perfusion are substantial contribut

In vivo Study of the Absorption of Seawe
✍ D. Bougle; M. Boudey; P. Arhan; F. Bureau; D. Neuville; M. Drosdowsky 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 174 KB 👁 2 views

The intestinal absorption of seaweed minerals (Ca, Zn, Fe) was compared with their inorganic salts, in YI'YO, using a perfused intestinal loop in the rat. A similar uptake of Ca from both sources was observed (19.1k21.0 vs 9.9k14.7 pmoVcm/min, NS), (meankl SD), as for Zn (38.8i26.5 vs 47.4k35.0 p,mo

In vivo time course studies of the tissu
✍ Patrick W. Stroman; Jean-Claude Dorvil; Yves Marois; Nicolas Poddevin; Robert Gu 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 164 KB 👁 1 views

Magnetic resonance (MR) imaging and relaxation time measurements of bioresorbable implants made of polylactic acid (PLA), as well as the surrounding tissues, were carried out over a period of 6 months to monitor the implant state and the body's responses, and to determine how these processes are ref