## Abstract The purpose of this study was to evaluate the usefulness of multishot echo‐planar imaging in detecting liver tumors in comparison with respiratory triggered T2‐weighted fast‐spin‐echo (FSE) imaging. Thirty‐two patients with 70 focal liver lesions were imaged using a 1.5‐T high speed MR
MR of focal liver lesions: Comparison of breath-hold and non-breath-hold hybrid rare and conventional spin-echo T2-weighted pulse sequences
✍ Scribed by Kenneth D. Carpenter; Shane E. Macaulay; Scott J. Schulte; Richard G. Obregon; Rendon C. Nelson; Howard E. Simon; Udo P. Schmiedl
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 896 KB
- Volume
- 6
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
To compare liver lesion detection rates, tissue signal and noise data, and qualitative parameters for breathhold (BH) and non‐breath‐hold (NBH) hybrid rapid acquisition with relaxation enhancement (RARE) and conventional spin‐echo (CSE) T2‐weighted (CSE‐T2) MR sequences, 20 patients were imaged using all three sequences. Lesion detection rates were 73.5% for the CSE‐T2 sequence and 81.1% and 88.6% for the BH‐RARE and NBH‐RARE sequences, respectively (P = .027). Mean lesion‐to‐liver signal‐difference‐to‐noise ratio for the NBH‐RARE sequence was 14.0 ± 11.5, significantly greater than 9.8 ± 7.8 obtained for the BH‐RARE sequence (P = .050) and 9.0 ± 6.2 obtained for the CSE‐T2 sequence (P = .015). The NBH‐RARE sequence demonstrated fewer artifacts and greater overall image quality compared to the CSE‐T2 sequence. The NBH‐RARE sequence is a useful alternative to the CSE‐T2 sequence providing a higher mean lesion‐to‐liver signal‐difference‐to‐noise ratio and lesion detection rate and better overall image quality.
📜 SIMILAR VOLUMES
## Abstract The purpose of our study was to compare the value of respiratory‐triggered fast spin‐echo, breath‐hold single‐shot fast spin‐echo, and breath‐hold fast‐recovery fast spin‐echo sequences in detecting hepatic lesions. Fat‐suppressed T2‐weighted magnetic resonance (MR) images obtained with
## Abstract In 49 patients who had pelvic abnormalities, breath‐hold T2‐weighted fast‐recovery (FR)‐fast spin‐echo (FSE) (imaging time = 24 sec) and nonbreath‐hold FSE MR images (2 min 8 sec) were compared qualitatively (on a four‐point scale) and quantitatively (using signal‐to‐noise ratios (SNRs)
## Abstract Three rapid T1‐weighted gradient‐echo techniques for imaging of the liver were compared: fast low‐angle shot (FLASH) and section‐selective (SSTF) and non‐section‐selective (NSTF) inversion‐recovery TurboFLASH. Ten healthy volunteers were imaged at 1.5 T, with breath‐hold images acquired
## Abstract In 24 patients presenting with 55 renal lesions (mean size, 20.8 mm), single‐breath‐hold (SBH) fast spin‐echo (FSE) techniques allowing T1 and T2 images to be produced within 20 and 23 sec, respectively, were compared with routine non‐breath‐hold (NBH) spin‐echo (SE) T1 and NBH‐FSE T2 s
## Abstract The purpose of this study was to quantitatively compare the hepatic contrast characteristics of conventional spin‐echo (CSE) and fast spin‐echo (FSE) sequences with breath‐hold T2‐weighted images acquired with half‐Fourier turbo spin echo (HASTE). Forty‐five patients were examined with