๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Motor unit action potential duration and muscle length

โœ Scribed by Daniel Dumitru; John C. King


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
155 KB
Volume
22
Category
Article
ISSN
0148-639X

No coin nor oath required. For personal study only.

โœฆ Synopsis


Motor unit action potential (MUAP) components are investigated by means of single fiber computer simulations and clinical measurements. The single fiber simulations have essentially full bandwidth without noise, whereas the clinical measurements were made with a 3-10,000-Hz bandwidth utilizing approximately 1000 averages to reduce noise optimally. These parameters allow the recording of a MUAP's complete "physiologic" duration including its very slow onset and termination. The simulation results demonstrate a constant waveform onset regardless of the electrode's recording location along the fiber. A far-field potential is initiated when the action potential encounters the muscle fiber's termination. The simulated waveform's and clinically recorded MUAP's near-field component extends between the potential's onset and its corresponding far-field potential's onset. This near-field component's duration should vary with fiber length, and this prediction is clinically confirmed by measuring three different muscle lengths. The far-field potential reveals a constant duration, independent of fiber length, and appears to be associated with the muscle fiber's intracellular action potential duration. A more complete understanding of the components contributing to MUAP duration should provide a more fundamental basis for quantitative clinical MUAP duration measurements.


๐Ÿ“œ SIMILAR VOLUMES


Motor unit action potential components a
โœ Daniel Dumitru; John C. King; William E. Rogers ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 165 KB ๐Ÿ‘ 2 views

Motor unit action potentials (MUAPs) recorded from the same motor unit at two distances along the biceps brachii muscle with monopolar needle electrodes at high amplifier gains (20 microV/division) and averaged 2000-3000 times reveal total potential durations of 39.6 +/- 4.6 ms. In addition, the ter

Comparison of single-fiber and macro ele
โœ Daniel Dumitru; John C. King; Sanjeev D. Nandedkar ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 134 KB ๐Ÿ‘ 2 views

The factors contributing to the duration of a motor unit action potential (MUAP) are believed to be well known, with both manual measurements and computer simulations agreeing with respect to MUAP durations approaching 10 ms. In this investigation, it is clearly demonstrated that use of a wide-open

Detecting single fiber contributions to
โœ Daniel William Stashuk ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 284 KB ๐Ÿ‘ 2 views

The ability to detect muscle fiber action potential (MFAP) contributions to motor unit action potentials (MUAPs) measured using single fiber (SF) and concentric needle (CN) electrodes was studied using simulated MUAPs. Various MFAP-acceleration thresholds were used to define significant fiber contri