Motor unit action potentials (MUAPs) recorded from the same motor unit at two distances along the biceps brachii muscle with monopolar needle electrodes at high amplifier gains (20 microV/division) and averaged 2000-3000 times reveal total potential durations of 39.6 +/- 4.6 ms. In addition, the terminal segment for each of these two MUAPs contained a late far-field potential with a mean duration of 23.8 +/- 4.1 ms. Computer simulations of MUAPs suggest that this long-duration positive far-field mirrors the true morphology of the intracellular action potential (IAP), which is monophasic positive, possessing a terminal repolarization phase approaching 30 ms. This investigation suggests that the MUAP's physiologic duration is directly proportional to the muscle fiber length and the IAP's duration, which becomes manifest as a positive far-field potential when the IAP encounters the musculotendinous junction and slowly dissipates. The leading/trailing dipole model is used to explain qualitatively this study's quantitative clinical and computer simulation findings.


๐Ÿ“œ SIMILAR VOLUMES


Motor unit action potential duration and
โœ Daniel Dumitru; John C. King ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 155 KB ๐Ÿ‘ 1 views

Motor unit action potential (MUAP) components are investigated by means of single fiber computer simulations and clinical measurements. The single fiber simulations have essentially full bandwidth without noise, whereas the clinical measurements were made with a 3-10,000-Hz bandwidth utilizing appro

Comparison of single-fiber and macro ele
โœ Daniel Dumitru; John C. King; Sanjeev D. Nandedkar ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 134 KB ๐Ÿ‘ 1 views

The factors contributing to the duration of a motor unit action potential (MUAP) are believed to be well known, with both manual measurements and computer simulations agreeing with respect to MUAP durations approaching 10 ms. In this investigation, it is clearly demonstrated that use of a wide-open

Detecting single fiber contributions to
โœ Daniel William Stashuk ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 284 KB ๐Ÿ‘ 1 views

The ability to detect muscle fiber action potential (MFAP) contributions to motor unit action potentials (MUAPs) measured using single fiber (SF) and concentric needle (CN) electrodes was studied using simulated MUAPs. Various MFAP-acceleration thresholds were used to define significant fiber contri

The diagnostic power of motor unit poten
โœ G. Pfeiffer ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 172 KB ๐Ÿ‘ 1 views

The notion of a "myopathic" or "neuropathic" electromyogram (EMG) is usually based on qualitative visual and acoustical impressions. Conventional quantification defines abnormality but not diagnosis, which requires interpretation of patterns of change. Discriminant analysis is a model for this multi