Motor unit action potential (MUAP) components are investigated by means of single fiber computer simulations and clinical measurements. The single fiber simulations have essentially full bandwidth without noise, whereas the clinical measurements were made with a 3-10,000-Hz bandwidth utilizing appro
Motor unit action potential components and physiologic duration
โ Scribed by Daniel Dumitru; John C. King; William E. Rogers
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 165 KB
- Volume
- 22
- Category
- Article
- ISSN
- 0148-639X
No coin nor oath required. For personal study only.
โฆ Synopsis
Motor unit action potentials (MUAPs) recorded from the same motor unit at two distances along the biceps brachii muscle with monopolar needle electrodes at high amplifier gains (20 microV/division) and averaged 2000-3000 times reveal total potential durations of 39.6 +/- 4.6 ms. In addition, the terminal segment for each of these two MUAPs contained a late far-field potential with a mean duration of 23.8 +/- 4.1 ms. Computer simulations of MUAPs suggest that this long-duration positive far-field mirrors the true morphology of the intracellular action potential (IAP), which is monophasic positive, possessing a terminal repolarization phase approaching 30 ms. This investigation suggests that the MUAP's physiologic duration is directly proportional to the muscle fiber length and the IAP's duration, which becomes manifest as a positive far-field potential when the IAP encounters the musculotendinous junction and slowly dissipates. The leading/trailing dipole model is used to explain qualitatively this study's quantitative clinical and computer simulation findings.
๐ SIMILAR VOLUMES
The factors contributing to the duration of a motor unit action potential (MUAP) are believed to be well known, with both manual measurements and computer simulations agreeing with respect to MUAP durations approaching 10 ms. In this investigation, it is clearly demonstrated that use of a wide-open
The ability to detect muscle fiber action potential (MFAP) contributions to motor unit action potentials (MUAPs) measured using single fiber (SF) and concentric needle (CN) electrodes was studied using simulated MUAPs. Various MFAP-acceleration thresholds were used to define significant fiber contri
The notion of a "myopathic" or "neuropathic" electromyogram (EMG) is usually based on qualitative visual and acoustical impressions. Conventional quantification defines abnormality but not diagnosis, which requires interpretation of patterns of change. Discriminant analysis is a model for this multi