## Abstract For diffusion‐weighted magnetic resonance imaging and under circumstances where patient movement can be modeled as rigid body motion, it is shown both theoretically and experimentally that translations and rotations produce phase errors which are zero‐ and first‐order, respectively, in
Motion correction and the use of motion covariates in multiple-subject fMRI analysis
✍ Scribed by Tom Johnstone; Kathleen S. Ores Walsh; Larry L. Greischar; Andrew L. Alexander; Andrew S. Fox; Richard J. Davidson; Terrence R. Oakes
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 701 KB
- Volume
- 27
- Category
- Article
- ISSN
- 1065-9471
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The impact of using motion estimates as covariates of no interest was examined in general linear modeling (GLM) of both block design and rapid event‐related functional magnetic resonance imaging (fMRI) data. The purpose of motion correction is to identify and eliminate artifacts caused by task‐correlated motion while maximizing sensitivity to true activations. To optimize this process, a combination of motion correction approaches was applied to data from 33 subjects performing both a block‐design and an event‐related fMRI experiment, including analysis: (1) without motion correction; (2) with motion correction alone; (3) with motion‐corrected data and motion covariates included in the GLM; and (4) with non–motion‐corrected data and motion covariates included in the GLM. Inclusion of covariates was found to be generally useful for increasing the sensitivity of GLM results in the analysis of event‐related data. When motion parameters were included in the GLM for event‐related data, it made little difference if motion correction was actually applied to the data. For the block design, inclusion of motion covariates had a deleterious impact on GLM sensitivity when even moderate correlation existed between motion and the experimental design. Based on these results, we present a general strategy for block designs, event‐related designs, and hybrid designs to identify and eliminate probable motion artifacts while maximizing sensitivity to true activations. Hum. Brain Mapp, 2006. © 2006 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
An automated retrospective image registration based on mutual information is adapted to a multislice functional magnetic resonance imaging (fMRI) acquisition protocol to provide accurate motion correction. Motion correction is performed by mapping each slice to an anatomic volume data set acquired i
## Abstract A new approach to understanding and reducing motion artifacts in magnetic resonance imaging (MRI) is introduced. This paper presents a novel technique for correcting generalized motion artifacts arising from translation, rotation, dilation, and compression, or any combination thereof. W
Dynamic contrast-enhanced MRI of atherosclerotic vessels after contrast agent injection may provide unique information regarding lesion structure and vulnerability. The high-resolution images necessary for viewing lesion substructures, however, are often corrupted by patient motion and low signal-to