𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Morphing steady-state free precession

✍ Scribed by O. Bieri; S. Patil; H.H. Quick; K. Scheffler


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
444 KB
Volume
58
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A novel concept for visualization of positive contrast originating from susceptibility‐related magnetic field distortions is presented. In unbalanced steady‐state free precession (SSFP) the generic, gradient‐induced dephasing competes with local gradient fields generated by paramagnetic materials. Thus, within the same image, SSFP may morph its own appearance from unbalanced to balanced SSFP (bSSFP) as a result of local gradient compensation. In combination with low to very low flip angles, unbalanced SSFP signals are heavily suppressed, whereas bSSFP locally produces very high steady‐state amplitudes at certain frequency offsets. As a result, bSSFP signals appear hyperintense on an almost completely dark background. In this study, the conceptual issues of local gradient compensation and frequency matching, as well as the feasibility of proper detection of marker materials for interventional MRI from hyperintense pixels locations, are evaluated both in vitro and in vivo. Signal dependencies of morphing SSFP on sequence parameters such as flip angle or repetition time are investigated theoretically and experimentally. In addition to passive tracking of interventional devices, morphing SSFP might also be a promising new concept for the generation of positive contrast from super‐paramagnetic iron oxide (SPIO) particles in contrast‐enhanced MRI as well as for particle tracking. Magn Reson Med, 2007. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Balanced steady state free precession fM
✍ Jin Hyung Lee 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 623 KB

## Abstract Balanced‐steady‐state free precession (b‐SSFP) functional magnetic resonance imaging (fMRI) encompasses several recently developed methods that utilize b‐SSFP acquisition for fMRI. Short repetition time (__T__~R~) and readout durations of b‐SSFP allow distortion‐free acquisition, 3D ima

Missing pulse steady-state free precessi
✍ S. Patz; S. T. S. Wong; M. S. Roos 📂 Article 📅 1989 🏛 John Wiley and Sons 🌐 English ⚖ 788 KB

A fast imaging technique, missing pulse steady-state free precession (MP-SSFF'), is described. MP-SSFP is one of a class of steady-state free precession techniques in which every nth RF pulse is missing. MP-SSFF' has been implemented for the case where every third R F pulse is omitted: ). A RF-refo

Frequency-modulated steady-state free pr
✍ D.L. Foxall 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 800 KB

Exploration of the possibilities of steady-state free precession (SSFP) excitation has led to the discovery that it is tolerant of slow variations in spectral offset frequency. The effect has been used to eliminate banding artifacts from images obtained with the fully balanced SSFP imaging sequence.

Motion-insensitive, steady-state free pr
✍ Y. Zur; M. L. Wood; L. J. Neuringer 📂 Article 📅 1990 🏛 John Wiley and Sons 🌐 English ⚖ 788 KB

## Abstract Steady‐state free precession (SSFP) pulse sequences employing gradient reversal echoes and short repetition time (TR) between successive rf excitation pulses offer high signal‐to‐noise ratio per unit time. However, SSFP sequences are very sensitive to motion. A new SSFP method is presen

Steady state free precession magnetizati
✍ Oliver Bieri; Tallas C. Mamisch; Siegfried Trattnig; Klaus Scheffler 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 647 KB

## Abstract The formerly proposed concept for magnetization transfer imaging (MTI) using balanced steady‐state free precession (SSFP) image acquisitions is in this work extended to nonbalanced protocols. This allows SSFP‐based MTI of targets with high susceptibility variation (such as the musculosk