𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Model for retention and efficiency in open-tubular supercritical fluid chromatography

✍ Scribed by Donald P. Poe


Publisher
Elsevier Science
Year
1992
Tongue
English
Weight
1022 KB
Volume
625
Category
Article
ISSN
1873-3778

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


The effects of the column pressure drop
✍ Janssen, Hans-Gerd ;Snijders, Henri M. J. ;Rijks, Jacques A. ;Crarners, Carel A. πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 766 KB

## Abstract The effects of the pressure drop across the column on retention and efficiency in SFC have been studied. Numerical methods are described which enable the prediction of hold‐up time and pressure drop in both packed and open tubular columns. Predictions of both hold‐up time and pressure d

Compressibility effects in packed and op
✍ Janssen, Hans-Gerd ;Snijders, Henri ;Cramers, Carel ;Schoenmakers, Peter πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 798 KB

## Abstract The influence of the pressure drop on the efficiency and speed of analysis in packed and open tubular supercritical fluid chromatography (SFC) is described: methods previously developed to describe the effects of mobile phase compressibility on the performance of open tubular columns in

Preservation of column efficiency when u
✍ Iina J. Koski; Karin E. Markides; Milton L. Lee πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 719 KB

## Abstract The use of small internal diameter precolumns (11–25‐μm i. d.) helped solute focussing when using solvent vent sample introduction in open tubular column supercritical fluid chromatography (SFC). Column efficiencies were similar to those obtained with split injection (3000–5000 plates m

Retention in capillary supercritical flu
✍ Chester, T. L. ;Innis, D. P. πŸ“‚ Article πŸ“… 1985 πŸ› John Wiley and Sons 🌐 English βš– 501 KB

The data so far published on this subject are not very satisfactory [S-lo]. Not only the results but also the dimensions used for expression of enzyme activities differ considerably and are confusing. 5a-reducing enzymes are commonly evaluated by measuring the metabolic conversion rates of a labeled

Optimization of internal valve injection
✍ Jari P. Tuominen; Karin E. Markides; Milton L. Lee πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 738 KB

As in the case of all chromatographic methods, the ideal sample introduction method for supercritical fluid chromatography (SFC) would provide a narrow and sharp solvent peak (or no solvent peak), quantitative transfer of the sample into the column, and high reproducibility. Elimination of the solve