## Abstract Cantilever beam and fourβpoint bend specimen geometries were used to experimentally determine the critical energy release rates for a plasma sprayed hydroxylapatiteβtitanium alloy (HAβTi alloy) interface. A locus of energy release rates as a function of crack tip phase angle was determi
Fracture tests of aluminum/epoxy dissimilar materials with an interface crack are carried out under comprehensive mixed mode conditions, using circular disk type (brazil-nut-sandwich) specimens under compression or tension loading in various directions. The stress intensity factors for an interface