Microstructural investigation of bone?cement interface
β Scribed by Savarino, L. ;Stea, S. ;Ciapetti, G. ;Paganetto, G. ;Donati, M. E. ;Alvergna, P. ;Pizzoferrato, A.
- Publisher
- John Wiley and Sons
- Year
- 1995
- Tongue
- English
- Weight
- 518 KB
- Volume
- 29
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
We evaluated the microstructural characteristics of newly formed bone tissue at the interface with cement. The bonecement interfaces of the femoral components of nine hip prostheses retrieved after loosening were investigated by means of X-ray diffraction on microareas and microhardness. The bone far from the interface of two stable prostheses was used as a control. The newly formed bone adjacent to cement in the loosened prostheses showed a maturity degree lower than that of bone adjacent to cement in stable prostheses. The lattice parameters of bone apatite did not show significant variations as compared to the reference values. Bone trabeculae at the interface with loosened prostheses often showed an osteoid lining characterized by a strongly demineralized lamellar and haversian structure. Radioopaque cement particles are sometimes found in the trabecular bone tissue around the prosthesis.
π SIMILAR VOLUMES
## Abstract Despite the widespread use of cement as a means of fixation of implants to bone, surprisingly little is known about the micromechanical behavior in terms of the local interfacial motion. In this work, we utilized digital image correlation techniques to quantify the micromechanics of the
## Abstract The cementβbone interface plays an important role in load transfer between cemented implant systems and adjacent bone, but little is known about the micromechanical behavior of this interface following in vivo service. Small samples of postmortemβretrieved cementβbone specimens from cem
## Abstract Quantitative information regarding the interface strength and degree of cement penetration associated with cement viscosity during total hip arthroplasty is limited. The aim of the present study was to determine the effect of the viscosity of bone cement at the time of implantation on t
## Abstract Loosening is recognized as one of the primary sources of total hip replacement (THR) failure. In this study the influence of the bone surface texture on loosening of the cement/bone interface was studied. Model cemented hip replacements were prepared and subjected to cyclic loads that i