Microfabricated glucose, lactate, glutamate and glutamine thin-film biosensors
โ Scribed by Th. Schalkhammer; Ch. Lobmaier; B. Ecker; W. Wakolbinger; E. Kynclova; G. Hawa; F. Pittner
- Book ID
- 103960536
- Publisher
- Elsevier Science
- Year
- 1994
- Tongue
- English
- Weight
- 500 KB
- Volume
- 19
- Category
- Article
- ISSN
- 0925-4005
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
Amperometric enzyme sensors for lactate, glutamate and glutamine were constructed using rhodinised carbon electrodes. All three sensors operated at a potential of +400 mV (Ag/AgCl). Lactate sensors were constructed using lactate oxidase immobilized in hydroxyethylcellulose, overlaid with a cellulose
Integrated thin-film glucose and lactate sensors were produced using thin photo-pattemable multi-enzyme membranes. The glucose and lactate sensors are based on the measurement of H,O\* on a Pt electrode produced by the enzymes glucose oxidase (GOD) and lactate oxidasc (LOD), respectively, which were
Solid-state technology and pulse electroplating were used to fabricate a glucose biosensor based on hydrogen peroxide detection. This glucose biosensor was composed of thin-film electrodes, and enzyme-immobilized and deactivated enzyme-immobilized membranes. The electrodes were fabricated by metalli