๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Micro-electrospray mass spectrometry: ultra-high-sensitivity analysis of peptides and proteins

โœ Scribed by Mark R. Emmett; Richard M. Caprioli


Publisher
Elsevier Science
Year
1994
Tongue
English
Weight
711 KB
Volume
5
Category
Article
ISSN
1044-0305

No coin nor oath required. For personal study only.

โœฆ Synopsis


A "micro-electrospray" ionization source has been developed that markedly increases the sensitivity of the conventional electrospray source. This was achieved by optimization of the source to accommodate nanoliter flow rates from 300 to 800-nL/min spraying directly from a capillary needle that, for the analysis of peptides, contained C18 liquid chromatography packing as an integrated concentration-desalting device. Thus, a total of 1 fmol of methionine enkephalin was desorbed from the capillary column spray needle, loaded as a 10-ฮผL injection of 100-amol/ฮผL solution. The mass spectrum showed the M + H ion at m/z 574.2 with a signal-to-noise ratio of better than 5:1 from a chromatographic peak with a width of about 12 s. A narrow range (15-u) tandem mass spectrum was obtained for methionine enkephalin from the injection of 500 amol, and a full-scan tandem-mass spectrum was obtained from 50 fmol. For proteins, the average mass measurement accuracy was approximately 100-200 ppm for the injection of 2.5 fmol of apomyoglobin and 20-40 ppm for 200 fmol. Carbonic anhydrase B and bovine serum albumin showed similar mass measurement accuracies.


๐Ÿ“œ SIMILAR VOLUMES


Analysis of Hydrophobic Proteins and Pep
โœ Johann Schaller; Bernhard Christian Pellascio; Urs Peter Schlunegger ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 465 KB ๐Ÿ‘ 2 views

Bacterioopsin (BO) from Halobacterium halobium, as well as its V8-protease and CNBr fragments from the C-terminal region, were used to establish appropriate conditions for the mass determination of membrane proteins and peptides by electrospray mass spectrometry (ESI-MS). Of the tested solvents neat

High-sensitivity analysis and sequencing
โœ Marina, Anabel; Garcรญa, Miguel Angel; Albar, Juan Pablo; Yagรผe, Jesรบs; Lรณpez de ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 203 KB ๐Ÿ‘ 2 views

This paper describes experience with the commercially available LCQ quadrupole ion trap mass spectrometer applied to the o โ€ -line analysis of peptides and proteins. The standard front end of the electrospray probe was replaced with a micromanipulator which, with the aid of a magnifying device, allow

Analysis of salivary peptides using HPLC
โœ Rui Vitorino; M. Joรฃo C. Lobo; Josรฉ A. R. Duarte; A. J. Ferrer-Correia; Pedro M. ๐Ÿ“‚ Article ๐Ÿ“… 2004 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 225 KB

## Abstract Salivary peptides are involved in a wide range of functions constituting the ๏ฌrst line of defence of oral cavity and precursors of dental pellicle formation. The presence of mucins in saliva makes dif๏ฌcult the analysis of the proteic content. This is due mainly to aggregation phenomenon