The proton spectroscopic imaging technique that uses read gradient during acquisition was used for the measurement of the proton spectra in the lumbar and thoracic part of the spine of a patient with breast cancer without known skeletal metastases. The bone marrow fat/water ratios were evaluated in
Methods and applications of diffusion imaging of vertebral bone marrow
✍ Scribed by José G. Raya; Olaf Dietrich; Maximilian F. Reiser; Andrea Baur-Melnyk
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 475 KB
- Volume
- 24
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Diffusion‐weighted imaging (DWI) is an MRI technique that is sensitive to random water movements at spatial scales far below typical MRI voxel dimensions. DWI is a valuable tool for the diagnoses of diseases that involve alterations in water mobility. In the spine, DWI has proven to be a highly useful method for the differential diagnosis of benign and malignant compression fractures. In these pathologies, the microscopic structure of bone marrow is altered in a very different ways, leading to different water mobility, which can be depicted by DWI. Most of the pulse sequences developed for MRI can be adapted for DWI. However, these DWI‐adapted sequences are frequently affected by artifacts, mostly caused by physiological motion. Therefore, the introduction of additional correction techniques, or even the development of new sequences is necessary. The first part of this article describes the principles of DWI and the sequences used for DWI of the spine: spin echo (SE), turbo spin echo (TSE), single‐shot echo planar imaging (EPI), and steady‐state free precession (SSFP) sequences. In the second part, clinical applications of DWI of the spinal bone marrow are extensively discussed. J. Magn. Reson. Imaging 2006. © 2006 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose: To determine the reproducibility of proton MR spectroscopy (^1^H‐MRS) for assessing vertebral bone marrow adiposity at 3 Tesla (T); to evaluate variation of marrow adiposity at different vertebral levels; and to demonstrate the feasibility of using ^1^H‐MRS at 3T for evalua
## Abstract Directionally‐ordered cellular structures that impede water motion, such as cell membranes and myelin, result in water mobility that is also directionally‐dependent. Diffusion tensor imaging characterizes this directional nature of water motion and thereby provides structural informatio