𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Method of separation of anthocyanins in red wines by HPLC

✍ Scribed by Drdák, M. ;Daučik, P. ;Simko, P. ;Karovičová, J. ;Rajniaková, A.


Publisher
John Wiley and Sons
Year
1992
Tongue
English
Weight
128 KB
Volume
36
Category
Article
ISSN
0027-769X

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The selective and reproducible separation of anthocyanins is important not only from the analytical but also from the practical points of view, for judgment the origin of anthocyanins in products of the most frequently occurring cultures of Vitis vinifera.

This work deals with the selection of the suitable conditions for the separation of anthocyanins in red wines by HPLC using gradient elution to determine the optimal pH of the mobil phase to improve the detection in the visible range and the selectivity of the column.

In the works published up to now, tartaric acid, acetic acid, phosphoric acid and perchloric acid have been used in different systems to adjust the pH value, discussing the formation of a suitable elution strength and the aggressivity of the acids [1–5].


📜 SIMILAR VOLUMES


Analysis of anthocyanins in red wine by
✍ Drdák, M. ;Daučik, P. ;Karovičová, I. ;Šimko, P. ;Rajniaková, A. ;Mórová, E. 📂 Article 📅 1992 🏛 John Wiley and Sons 🌐 English ⚖ 138 KB

## Abstract Red wine represents a complicated system of phenolic compounds which give typical properties to individual varieties. Anthocyanin pigments represent a determinant group and therefore special attention is given to its analysis. The separation in an acceptable time, the selective separati

Deterrmination of anthocyanins and relat
✍ Paola Dugo; Olinda Favoino; Maria Lo Presti; Rosario Luppino; Giovanni Dugo; Lui 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 203 KB

## Abstract Anthocyanins and derived components of red wines were determined by microHPLC using a 1 mm ID HPLC column coupled on‐line with an MS detector equipped with an ESI (ElectroSpray Ionisation) source. The use of microcolumn HPLC greatly enhanced detection performance, allowing direct identi

Simultaneous separation and identificati
✍ S. Pati; I. Losito; G. Gambacorta; E. La Notte; F. Palmisano; P. G. Zambonin 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 258 KB

## Abstract Samples of raw red wine (__Primitivo di Manduria__, Apulia, Southern Italy) were analysed without any pre‐treatment (except 1 : 2 dilution with water) using HPLC with detection based on UV absorbance and Electrospray Ionisation Sequential Mass Spectrometry (ESI‐MS^__n__^, with __n__ = 1

Identification of dimeric anthocyanins a
✍ Cristina Alcalde-Eon; María Teresa Escribano-Bailón; Celestino Santos-Buelga; Ju 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 340 KB 👁 1 views

## Abstract High‐pressure liquid chromatography‐diode array detector‐electrospray ionisation/ion trap mass spectrometry (HPLC‐DAD‐ESI/MS^__n__^) analyses carried out in red wine fractions revealed the existence of dimeric anthocyanins (A–A^+^), previously detected in grape skin, and allowed the det

Determination of trans -Resveratrol Conc
✍ André A. Souto; Manuel C. Carneiro; Marcus Seferin; Marcos J.H. Senna; Andressa 📂 Article 📅 2001 🏛 Elsevier Science 🌐 English ⚖ 191 KB

The levels of trans-resveratrol in 36 commercial red wines produced in the southern region of Brazil have been measured using a direct injection isocratic UV-HPLC method. The concentration of trans-resveratrol ranged from 0.82 to 5.75 mg/L with a mean value of 2.57 mg/L (R.S.D.%"1.99).