## Abstract Stainless steel is the alloy most frequently used for fracture fixation devices (FFD). We aimed to verify if the ion release evaluation could be a surrogate marker of performance and could allow an early detection of implant failure in patients with stainless steel FFD. We measured the
Little is known of the release of trace elements in vivo from dental implant materials. Conflicting data have been reported in the literature as to the levels of trace elements released and their potential consequences, mainly because of sampling and analytical methodological errors. In this study m