We present results for direct on-line detection of semi-volatile compounds in air using membrane introduction ion trap mass spectrometry. Brief sampling periods of 10 seconds to 3 minutes produced linear and reproducible data for concentrations ranging from parts-per-trillion to parts-per-billion by
Membrane inlet mass spectrometry of volatile organohalogen compounds in drinking water
✍ Scribed by P. Bocchini; R. Pozzi; C. Andalò; G. C. Galletti
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 87 KB
- Volume
- 13
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
✦ Synopsis
The analysis of organic pollutants in drinking water is a topic of wide interest, reflecting on public health and life quality. Many different methodologies have been developed and are currently employed in this context, but they often require a time-consuming sample pre-treatment. This step affects the recovery of the highly volatile compounds. Trace analysis of volatile organic pollutants in water can be performed 'on-line' by membrane inlet mass spectrometry (MIMS). In MIMS, the sample is separated from the vacuum of the mass spectrometer by a thin polymeric hollow-fibre membrane. Gases and organic volatile compounds diffuse and concentrate from the sample into the hollow-fibre membrane, and from there into the mass spectrometer. The main advantages of the technique are that no pre-treatment of samples before analysis is needed and that it has fast response times and on-line monitoring capabilities. This paper reports the set-up of the analytical conditions for the analysis of volatile organohalogen compounds (chloroform, bromoform, bromodichloromethane, chlorodibromomethane, tetrachloroethylene, trichloroethylene, 1,1,1-trichloroethane, and carbon tetrachloride). Linearity of response, repeatability, detection limits, and spectra quality are evaluated.
📜 SIMILAR VOLUMES
The measurement by membrane inlet mass spectrometry of gases dissolved in water is hampered by high and unstable background signals caused by residual gases whose origins have not been thoroughly investigated. We propose that significant amounts of gases are created by chemical reactions at the hot
Figure 3. The release of NO-treated plasma after the addition of HgCl 2 in 2 M HCl. Analysis was performed as described in the legend for Fig. 2. The very first injection (À1) represents a blank injection of water before introducing NO.
In order to detect highly polar organic compounds in water using membrane inlet mass spectrometry (MIMS), we designed a desorption chemical ionization ion source with a tubular polyacrylonitrile membrane positioned in the center of the chemical ionization (Cl) ion plasma. With this system we have fo